12.0    troubleshooting

symptom

problem

test solution

Flames are consistently too 
large or too small. 
Carboning occurs.

Appliance is over-fi red or 
underfi red.

 

-

Check pressure readings: 

Inlet pressure can be checked by turning screw (A) counter-clockwise 
2 or 3 turns and then placing pressure gauge tubing over the test 
point. Gauge should read as described on the chart below. Check that 
main burner is operating on ‘HI’. Outlet pressure can be checked the 
same as above using screw (B). Gauge should read as described on 
the chart below. Check that main burner is operating on ‘HI’. 

AFTER 

TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS 
CLOCKWISE FIRMLY TO RESEAL. DO NOT OVER TORQUE.

Leak test with a soap and water solution.

Air shutter improperly adjusted.

 

-

Return air shutter to specifi ed opening, see “venturi adjustment” section.

Carbon is being deposited 
on glass, logs, rocks, 
media or combustion 
chamber.

Air shutter has become blocked.

 

-

Ensure air shutter opening is free of lint or other obstructions.

Flame is impinging on the 
glass, logs, rocks, media or 
combustion chamber.

 

-

Check that the logs are correctly positioned.

 

-

Check for ceiling or oscillating fans that may be infl uencing the fl ame.

 

-

Open air shutter to increase the primary air. See “venturi adjustment” 
section.

 

-

Check the input rate: check the manifold pressure and orifi ce size as 
specifi ed by the rating plate.

Exhaust fumes smelled in 
room, headaches.

Not enough combustion air.

 

-

Increase fresh air supply. (Use one of the methods described in ANSI 
Z223.1 / NFPA 54 or the applicable local code.)

Not enough ventilation air.

 

-

Increase fresh air supply. (Use one of the methods described in ANSI 
Z223.1 / NFPA 54 or the applicable local code.)

Flame is impinging on the logs or 
combustion chamber.

 

-

Check that the logs are correctly positioned.

 

-

Open air shutter to increase the primary air. See “venturi adjustment” 
section.

 

-

Check the input rate: check the manifold pressure and orifi ce size as 
specifi ed by the rating plate values.

Main burner will not light; 
or is slow to light, noisy 
pilot.

Inlet pressure too high.

 

-

Adjust inlet pressure to ensure 7.0” W.C. (17.4mb) at gas valve for 
natural gas and 13.0” W.C. (32.4mb) for propane.

Pilot fl ame blowing off, missing 
thermopile.

Pilot is not functioning 
properly.

Pilot has been painted

 

-

Using a piece of sandpaper or emery cloth remove the paint from the 
pilot hood, ignitor and fl ame sensor.

Pilot goes out while 
standing; Main burner is in 
‘OFF’ position.

Gas piping is undersized.

 

-

Turn on all gas appliances and see if pilot fl ame fl utters, diminishes or 
extinguishes, especially when main burner ignites. Monitor appliance 
supply working pressure.

 

-

Check if supply piping size is to code. 

 

-

Correct all undersized piping.

Pilot fl ame is not large enough.

 

-

ODS Burner requires checking.

INSERT 

PHOTO 

OF VALVE 

HERE

Pressure

Natural Gas 

(inches)

Natural Gas 

(millibars)

Propane 

(inches)

Propane

(millibars)

Inlet

*  7”

(MIN. 4.5”)

17.4mb 

(MIN. 11.2mb)

13”

(MIN. 11”)

32.4mb 

(MIN. 27.4mb)

Outlet

3.5”

8.7mb

10”

24.9mb

* Maximum inlet 

pressure not to 

exceed 13”

• 

Always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door open or removed.

• 

Turn off the appliance completely and let cool before servicing. Only a qualifi ed service person should service and 
repair this electric appliance.

• 

Appliance may be hot, do not service until appliance has cooled. 

• 

Do not use abrasive cleaners.

!

WARNING

P

I

PILOT

N

O

L

O

T

H I

LO

FF O

A

B

PILOT SCREW

Содержание Knightsbridge VF Series

Страница 1: ...our gas supplier call the re department Installation and service must be performed by a quali ed installer service agency or the supplier This is an unvented gas red heater that uses air oxygen from t...

Страница 2: ...burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to an appliance or stove install an adjustable safety gate to keep toddlers young children and...

Страница 3: ...anemia those under the in uence of alcohol those at high altitudes are more affected by carbon monoxide than others Failure to keep the primary air opening s of the burner s clean may result in sootin...

Страница 4: ...er installation 15 6 1 switch and bracket installation 16 7 0 operation 17 8 0 adjustment 18 8 1 venturi adjustment 18 8 2 ame characteristics 18 9 0 maintenance 19 9 1 oxygen depletion sensor pilot c...

Страница 5: ...nough fresh air is available This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certi ed kit is used...

Страница 6: ...equipped with a power cord it must be connected into a properly grounded receptacle The grounding prong must not be removed from the cord plug As long as the required clearance to combustibles is main...

Страница 7: ...ndards ANSI Z21 11 2 2016 VOLUME II for Unvented Room Heaters A 6 B 6 C 2 D 4 L O T N O P O I F F O L IH FLAME ADJUSTMENT NOT FOR USE WITH SOLID FUEL SERIAL NUMBER GVFS60 W385 0184 I ON OFF CONTROL IG...

Страница 8: ...kid SHIPPINGBRACKET 1 5 shipping bracket The top casting is not fastened to the appliance assembly It simply sits on the appliance as a lid For shipping purposes it is held in place by plastic strappi...

Страница 9: ...truction unless provisions are provided for adequate combustion and ventilation air The National Fuel Gas Code ANSI Z223 1 NFPA 54 de nes a con ned space as a space whose volume is less than 50 cubic...

Страница 10: ...Code ANSI Z223 1 NFPA54 or the applicable local code Room Volume Length x Width x Height Max BTU hr Room Volume x 1000 50 If for example The length of the rooms is 5 feet 1 5m The width of Room 1 is 1...

Страница 11: ...res above 1 2 PSIG Valve settings have been factory set do not change Installation and servicing to be done by a quali ed installer Move the appliance into position and secure If equipped with a ex co...

Страница 12: ...a convenient location Route a 2 strand solid core millivolt wire from the valve to the wall switch or millivolt thermostat The recommended maximum lead length depends on wire size WIRE SIZE MAX LENGTH...

Страница 13: ...nt repeat in reverse order and ensure bottom locating tabs engage on either leg SCREEN SECURING BOLTS CAST FRONT SECURING BOLTS BOTTOM LOCATING TABS TOP FRONT RETAINER 5 0 nishing 5 1 cast front remov...

Страница 14: ...place onto the front of the burner Care should be taken to shred the embers into thin small irregular pieces as only the exposed edges of the bre hairs will glow when exposed to direct ame however ca...

Страница 15: ...side of the blower housing F Remove the 2 screws from the side of the blower housing that you want the switch to be located on and re secure the on off switch Because the blower is thermally activated...

Страница 16: ...W415 1966 07 08 19 EN 16 blower installation 6 1 switch and bracket installation 1 3 CONNECT THE TWO WIRES TO THE SWITCH TERMINALS 2...

Страница 17: ...n repeat steps E through I J With pilot lit turn gas knob counter clockwise to the ON position K If equipped with the ame adjustment valve push and turn the knob to high L Turn on all electrical power...

Страница 18: ...re yellow ame but can lead to carbonization Opening the air shutter will cause a more blue ame but can cause ame lifting from the burner ports The ame may not appear yellow immediately allow 15 to 30...

Страница 19: ...d logs rocks or glass Failure to properly position the media may cause carboning which can be distributed in the surrounding living area inside the rebox and on exterior surfaces sur rounding vent ter...

Страница 20: ...replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts always give the following information Model Serial Number of appliance Instal...

Страница 21: ...urner ori ce 38 NG W456 0053 Burner ori ce 53 P W662 0001 ODS pilot assembly NG W680 0004 Thermopile W725 0030 Valve NG W725 0031 Valve P W662 0005 ODS pilot assembly P W357 0001 Piezo ignitor W135 08...

Страница 22: ...ar exactly as illustrated 2 1 Stocked Stocked F60 Thermostatic remote 6 3 1 2 4 5 6 8 7 8 F45 On off remote 7 GDS819KT Sandstone decorative brick panels ANI K Metallic black andirons 5 W660 0081 Therm...

Страница 23: ...y Use one of the methods described in ANSI Z223 1 NFPA 54 or the applicable local code Flame is impinging on the logs or combustion chamber Check that the logs are correctly positioned Open air shutte...

Страница 24: ...nk Pilot ame is not large enough Supply pressure too low Service or replace Oxygen Depletion Sensor System Correct piping and or regulator to provide correct pressure Ensure adequate supply pressure T...

Страница 25: ...aused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to the appliance combustion chamber heat exchanger plated trim or other components due to water weather damage...

Страница 26: ...W415 1966 07 08 19 EN 26 notes...

Страница 27: ...EN W415 1966 07 08 19 27 notes...

Страница 28: ...TI IN NG G O OV VE ER R 4 40 0 Y YE EA AR RS S A A A O O O O O OF F F F F F H H H H H H H HO O O O O OM M M M ME E E E E C C CO OM M MF F FO OR RT T P PR RO OD DU UC CT TS S 7200 Route Transcanadienne...

Отзывы: