30

W415-0153 / B / 06.10.10

5.2.1

  Place the back log into the 

fi

 rebox, pushing it as close 

to the 

fi

 rebox wall as possible and centered onto the 

log support pan.

5.2.2

  Place the front log on the ember screen lining up the 

studs with the holes on the bottom of the log.

 

NOTE: The ember screen is adjustable front to 
back. To avoid fl ame impingement on propane 
move the ember screen to the back most position. 
Loosen the two screws that secure the ember 
screen, move the screen back and retighten the 
screws. 

 

The glowing ember screen is positioned in the 

fl

 ame to maximize the glow effect. Even though it is 

constructed of the highest quality material, it is subject 
to deterioration over time and consequently will need to 
be replaced.  Replacement of the ember screen is not

             covered under the warranty policy

5.2.3

  Set the two cross-over logs into the pockets provided 

on both the front and rear logs as shown.

PHAZER

TM

 logs, glowing embers and charcoal embers exclusive to Wolf Steel Ltd. 

fi

 replaces, glow when 

exposed to direct 

fl

 ame and provide a unique and realistic glowing effect that is different in every installation. 

Use only certi

fi

 ed PHAZER

TM

 logs, glowing embers and charcoal embers available from your local authorized 

dealer / distributor. 

Log colours may vary. During the initial use of the appliance, the colours will become more uniform as colour 
pigments burn in during the heat activated curing process.

5.2 LOG 

PLACEMENT

!

WARNING

FAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE 

ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY 

DAMAGE OR PERSONAL INJURY.

LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE 

PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED 

IGNITION MAY OCCUR.

THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE. 

76.1A

1

2

3

4

Содержание Haliburton GDS28P

Страница 1: ...er flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in...

Страница 2: ...2 1 HORIZONTAL INSTALLATION 21 4 2 2 VERTICAL INSTALLATION 22 4 2 3 HORIZONTAL AIR TERMINAL INSTALLATION MODEL GDS28 22 4 2 4 VERTICAL AIR TERMINAL INSTALLATION 23 4 3 APPLIANCE VENT CONNECTION 24 4 4...

Страница 3: ...3 W415 0153 B 06 10 10 Door see DOOR CLOSING OPENING section Rating plate see RATING PLATE section Logo see LOGO PLACEMENT section Vent see VENTING section 1 0 INSTALLATION OVERVIEW...

Страница 4: ...and venting system are kept clean The appliance and its venting system should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to...

Страница 5: ...BE KEPT A MINIMUM OF 48 FROM THE FRONT FACE OF THE UNIT SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT AVOID CONTACT WHEN THE APPLIANCE IS OPERATING FIRE RISK EXPLOSION HAZARD HIGH...

Страница 6: ...llation if installed in accordance with the current standard CAN CSA Z240MH Series for gas equipped mobile homes in Canada or ANSI Z223 1 and NFPA 54 in the United States As long as the required clear...

Страница 7: ...sence of specific recommendations from the local authority having jurisdiction the certified high altitude input rating shall be reduced at the rate of 4 for each additional 1 000 ft Change in flame a...

Страница 8: ...UPPLIEDBYTHEMANUFACTURERWITHTHEAPPLIANCE AVERTISSEMENT N AJOUTEZ PASACET APPAREILAUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST APPAREIL PAR LE FABRICANT MINIMUM CLEA...

Страница 9: ...CE CLEARANCES TO VENT PIPE AND APPLIANCE IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3 FEET FOR BOTH VERTICAL AND HORIZONTAL RUNS USE SUPPORTS OR EQUIVALENT NON COMBUST...

Страница 10: ...rminal kit GD175 7 12 of venting included or 1 12 to 7 12 pitch roof terminal kit GD110 8 12 to 12 12 roof terminal kit GD111 flat roof terminal kit GD112 or periscope kit GD180 for wall penetration b...

Страница 11: ...11 W415 0153 B 06 10 10 3 2 TYPICAL VENT INSTALLATION 26 3 4 16 MINIMUM 40 FEET MAXIMUM 3 MINIMUM 26 3 4 29 MINIMUM 55 3 4 MINIMUM PLUS RISE 34 MAXIMUM See VENTING section...

Страница 12: ...ope must be installed so that when final grading is completed the bottom air slot is located a minimum 12 above grade The maximum allowable vent length is 10 9 7 3 3 SPECIAL VENT INSTALLATIONS 57 MINI...

Страница 13: ...ng neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 See chart for wider wall dimensions R 6 6 See chart for deeper wall dimensions The terminal shall not be installed o...

Страница 14: ...al to or greater than the horizontal run Vertical rise is less than horizontal run Vertical rise is equal to or greater than the horizontal run Vertical rise is less than horizontal run Horizontal run...

Страница 15: ...5 2 4 5 FT HO 03 three 90 elbows 90 03 270 90 5 4 FT HT HR HO 4 5 5 4 9 9 FT HT VT 9 9 11 20 9 FT Formula 1 HT VT 9 9 11 Formula 2 HT VT 40 FT 20 9 40 Since both formulas are met this vent configurati...

Страница 16: ...e 2 V1 VT 6 FT H1 3 FT H2 5 FT HR H1 H2 3 5 8 FT HO 03 two 90 elbows 90 03 180 90 2 7 FT HT HR HO 8 2 7 10 7 FT HT VT 10 7 6 16 7 FT Formula 1 HT 4 2 VT 4 2 VT 4 2 x 6 25 2 FT Formula 2 HT VT 24 75 FT...

Страница 17: ...the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet Example 6 V1 5 FT V2 6 FT V3 10 FT VT V1 V2 V3 5 6 10 21 FT H1 8 FT H2 2 5 FT HR H1 H2 8 2 5 10 5 FT HO 03 four 90 elbows 90 03 36...

Страница 18: ...3 2 1 1 5 4 5 FT H1 6 FT H2 2 FT HR H1 H2 6 2 8 FT HO 03 four 90 elbows 90 03 360 90 8 1 FT HT HR HO 8 8 1 16 1 FT HT VT 16 1 4 5 20 6 FT Formula 1 HT 3VT 3VT 3 x 4 5 13 5 FT 16 1 13 5 Since this form...

Страница 19: ...ollar of the termination cap must be connected to the air intake pipe Use Simpson Duravent Chimney Liner Termination Kit 923GK Base plate and Co Linear to Co Axial Adaptor Follow manufacturers Simpson...

Страница 20: ...PIPE RISK OF FIRE EXPLOSION OR ASPHYXIATION IMPROPER SUPPORT OF THE ENTIRE VENTING SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE USE VENT RUN SUPPORTS AND CONNECT VENT SECTIONS PER INSTALLATION INSTRUCTI...

Страница 21: ...firestop assembly Dry fit the firestop assembly before proceeding to ensure the brackets on the rear surface fit to the inside surface of the horizontal framing The length of the vent shield may be c...

Страница 22: ...materials such as insulation from filling up the 1 air space around the pipe 21 1 CAULKING VENT PIPE SHIELD FIRESTOP UNDERSIDE OF JOIST VENT PIPE COLLAR VENT PIPE SHIELD A Stretch the inner flex pipe...

Страница 23: ...tor leaving a min 3 4 of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector...

Страница 24: ...lation is completed An optional decorative black band is available for this use In the event that the venting must be disassembled care must be taken to reseal the venting 28 3 2 OVERLAP HIGH TEMPERAT...

Страница 25: ...PE TO PREVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFOR...

Страница 26: ...CHIMNEY VENT CONNECTOR NO NEW LINER NEEDED IF OLD LINER DIAMETER IS 4 5 SINGLE WALL OR B VENT B VENT GAS BURNING APPLIANCE VENT SYSTEM A CHIMNEY VENTING THIS APPLIANCE SHALL NOT VENT ANY SOLID FUEL B...

Страница 27: ...pplied I Unscrew the wire access cover plate from the rear right hand side below the firebox Remove and discard the gasket Remove the knockout from the cover plate and insert the protective bushing Pu...

Страница 28: ...oof and at least 2 feet higher than any wall roof building or obstacle within 10 feet horizontally 59 1A 3 FT MIN 3 FT MIN 3 FT MIN 3 FT MIN 10 FT OR MORE LESS THAN 10 FT FLAT ROOF WALL 2 FT MIN 10 FT...

Страница 29: ...OFF AND WAIT UNTIL APPLIANCE IS COOL TO THE TOUCH DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE 75 3 When installing the fire viewing door a simple procedure must be followed in order to not damage...

Страница 30: ...logs into the pockets provided on both the front and rear logs as shown PHAZERTM logs glowing embers and charcoal embers exclusive to Wolf Steel Ltd fireplaces glow when exposed to direct flame and pr...

Страница 31: ...Fine dust found in the bottom of the bag should not be used NOTE Charcoal embers are not to be placed on the burner 31 1 Tear the glowing embers into pieces and place onto the screen beneath the fron...

Страница 32: ...t fans in the home turn appliance blower off if equipped 6 0 2 Set controls to high and light the unit 6 0 3 Wait 5 minutes Light a match and extend it 1 into the hole located above the spill switch b...

Страница 33: ...control which has been under water WHAT TO DO IF YOU SMELL GAS Turn off all gas to the fireplace Open windows Do not try to light any appliance Do not touch any electric switch do not use any phone i...

Страница 34: ...heck that main burner is operating on HI AFTER TAKING PRESSURE READINGS TIGHTEN SCREWS FIRMLY TO SEAL DO NOT OVER TORQUE LEAK TEST 39 3 P I P I L O T N O L O T HI L O F F O A B PILOT SCREW PILOT BURNE...

Страница 35: ...UST ENVELOP UPPER 3 8 TO 1 2 OF FLAME SENSOR FLAME SENSOR ELECTRODE 54 1 7 4 RESTRICTING VERTICAL VENTS MODEL GDS28 Vertical installations may display a very active flame If this appearance is not des...

Страница 36: ...gs rocks or glass Failure to properly position the media may cause carboning which can be distributed in the surrounding living area 6 Check to see that the main burner ignites completely on all openi...

Страница 37: ...neither pinched nor interfere with the blower operation Re secure the air intake manifolds INSTALLATION THROUGH THE FIREBOX REPLACEMENT BLOWER ACCESS GASKET IS REQUIRED Turn off the electrical power a...

Страница 38: ...S IS A FAST ACTING THERMOCOUPLE IT IS AN INTEGRAL SAFETY COMPONENT REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING COMMON COMPONENTS REF NO PART NO DESCRIPTION 1 W725 0...

Страница 39: ...ETER 43 BM3730 BLACK TRIM COLLAR 44 W010 0300 10 ALUMINUM FLEX LINER C W SPACERS 4 DIAMETER 45 W025 0003 DECORATIVE BLACK BAND GD180 PERISCOPE TERMINAL KIT 36 BM6790 90 ELBOW 7 DIAMETER 46 GD 201 PERI...

Страница 40: ...IGH TEMPERATURE SEALANT 55 W660 0081 THERMOSTAT SWITCH 56 F40 ON OFF REMOTE 57 F50 THERMOSTATIC REMOTE 58 GS328 1K DOOR BLACK 58 GS328 1G DOOR GOLD 58 GS328 1SS DOOR SATIN CHROME 59 W175 0124 CONVERSI...

Страница 41: ...41 W415 0153 B 06 10 10 28 P I P I L O T N O L O T HI L O F F O 4 5 6 7 1 3 27 29 30 12 14 16 13 15 25 22 23 10 8 34 35 36 37 39 39 40 43 42 45 45 45 45 64 47 48 49 50 51 52 53 46 58 32 31 62...

Страница 42: ...y Loosen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Replace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch ther...

Страница 43: ...ames are very aggressive Door is ajar Ensure the mechanical means of securing the door is providing a tight seal Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has...

Страница 44: ...and should be removed as required Incorrect installation Ensure vent configuration is within prescribed venting parameters GDS28 SYMPTOM PROBLEM TEST SOLUTION Door Sticking Dirt dust adheres to the h...

Страница 45: ...of NAPOLEON with respect to the NAPOLEON gas heater and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEON neither assumes nor a...

Страница 46: ...46 W415 0153 B 06 10 10 12 0 SERVICE HISTORY 43 1...

Страница 47: ...47 W415 0153 B 06 10 10 44 1 13 0 NOTES...

Страница 48: ...48 W415 0153 B 06 10 10 44 1...

Отзывы: