Recommended to prevent condensation on windows and thermal breakage

**

**

**

**

**

It is recommended to use a heat shield and to maximize the distance to vinyl clad soffits.

***

***

***

***

***

The periscope GD-201 requires a minimum 18 inches clearance from an inside corner.

****

****

****

****

**** This is a recommended distance. For additional requirements check local codes.

††

Three feet above if  within 10 feet horizontally.

‡‡

A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family
dwellings and serves both dwellings.

† †

† †

† †

† †

† †

Permitted only if  the veranda, porch, deck or balcony is fully open on a minimum of  two sides beneath the floor.

†*

†*

†*

†*

†*

Recommenced to prevent recirculation of  exhaust products. For additional requirements check local codes.

A
B
C

D

E

F

G

H

I

J

K

L

M

N
O

12 INCHES

9 INCHES

12 INCHES*

18 INCHES**

12 INCHES**

0 INCHES

0 INCHES***

2 INCHES***

3 FEET****

3 FEET****

9 INCHES

3 FEET†

7 FEET****

12 INCHES****

16 INCHES

2 FEET†*

Clearance above grade, veranda porch, deck or balcony.

Clearance to windows or doors that open.

Clearance to permanently closed windows.

Vertical clearance to ventilated soffit located above the terminal within
a horizontal distance of 2 feet from the centerline of the terminal.

Clearance to unventilated soffit.

Clearance to an outside corner wall.

Clearance to an inside 

non

-combustible corner wall or protruding

non

-combustible obstructions (chimney, etc.).

Clearance to an inside combustible corner wall or protruding com-
bustible obstructions ( vent chase, etc.).

Clearance to each side of the centerline extended above the meter
/ regulator assembly.

Clearance to a service regulator vent outlet.

Clearance to a non-mechanical air supply inlet to the building or a
combustion air inlet to any other appliance.

Clearance to a mechanical air supply inlet.

Clearance above a paved sidewalk or paved driveway located on
public property unless fitted with a heat shield kit GD-301.

Clearance under a veranda, porch, deck or balcony.

Clearance above the roof.

Clearance from an adjacent wall including neighbouring buildings.

CANADIAN

U.S.A.

12 INCHES

12 INCHES

12 INCHES*

18 INCHES**

12 INCHES**

0 INCHES

0 INCHES***

2 INCHES***

3 FEET

6 FEET

12 INCHES

6 FEET

7 FEET‡

12 INCHES††

16 INCHES

2 FEET†*

INSTALLATIONS

Содержание Haliburton GDS28N

Страница 1: ...ada L4M 4Y8 705 721 1212 R 2000 Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not followed...

Страница 2: ...uld stay away to avoid burns or clothing ignition Supervise young children when they are in the same room as the stove Due to high temperatures the stove should be located out of traffic and away from...

Страница 3: ...Labour costs to the however requires the prior approval of an authorized company official Labour costs to the account of account of account of account of account of NAPOLEON NAPOLEON NAPOLEON NAPOLEON...

Страница 4: ...aler Do not substitute materials Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner Thereafter clean as required Do not clean glass when hot If the gl...

Страница 5: ...VENTING LENGTHS AND AIR TERMI NAL LOCATIONS Use only Wolf Steel or Simpson Dura Vent Model DV GS venting components Minimum and maximum vent lengths for both horizontal and vertical installations and...

Страница 6: ...d OFFSET INSTALLATION EXAMPLE FIGS 5 FIGURE4 If a first run of 72 inches is re quired using the First Vent Run on the chart shows that a maxi mum second run of 48 inches is allowable IF NECESSARY THE...

Страница 7: ...EET Clearance above grade veranda porch deck or balcony Clearance to windows or doors that open Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the termin...

Страница 8: ...sition apply sealant between the pipe and the firestop spacer 3 In the attic after the pipe has been installed slide the vent pipe collar down to cover up the open end of the shield and tighten This w...

Страница 9: ...rain cap 7 In the attic slide the vent pipe collar down to cover up the open end of the shield and tighten This will prevent any materials such as insulation from filling up the 1 air space around the...

Страница 10: ...e base For mobile home installations the fireplace must be fastened in place Use 10 screws inserted through the holes in the base to se cure It is recommended that the fireplace be secured in all inst...

Страница 11: ...ew the wire access cover plate from the rear right hand side of the firebox Remove and discard the gasket SEE FIGURE 25 Remove the knockout from the cover plate and insert the protective bushing Pull...

Страница 12: ...of or building within 10 feet FIGURE 26 This is a guideline only local venting codes should be followed which may differ in height and clearance requirements Continue with Gas Installation Page 13 INS...

Страница 13: ...IES TO CANADA ONLY L EFFICACITE CONSTANTE S APPLIQUENT SEULEMENT AU CANADA AFUE NG LP GN GP 64 65 MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY LES LONGUEURS HORIZ...

Страница 14: ...close to the firebox wall as possible and centered onto the log support pan FIGURES 31 FIGURES 30 Place the front log on the ember screen lining up the studs with the holes on the bottom of the log CA...

Страница 15: ...n MODEL GS28 ONLY SPILL SWITCH This is a thermally activated switch attached to the back of the chimney adapter which senses the change in temperature and shuts down the gas valve in the event of a se...

Страница 16: ...servicing the stove CAUTION Label all wires prior to disconnection when serv icing controls Wiring errors can cause improper and dan gerous operation Verify proper operation after servicing This stove...

Страница 17: ...neither pinched nor interfere with the blower operation Re se cure the air intake manifolds INSTALLATION THROUGH THE FIRE BOX Replacement blower access gasket is required 2 Open the lower control door...

Страница 18: ...el plate To access the venturi remove the air housing cover plate held on with 2 screws Take care not to damage the gasket Natural gas and propane models have air shutters set fully open Closing the a...

Страница 19: ...ABLE PIPE 7 DIA W500 0077 FIRESTOP WALL PLATE W020 0032 HARDWARE BRTC7 BRASS TRIM COLLAR BM6724 24 STOVE PIPE 7 DIAMETER W010 0300 10 ALUMINIUM FLEX LINER C W SPACERS 4 DIA W025 0001 DECORATIVE BRASS...

Страница 20: ...ARIABLE SPEED SWITCH GZ 552 REPLACEMENT BLOWER W030 0022 ACCENT BAR W200 0077 BLACK TRIVET GS28 W010 0459 ADAPTOR C W SPILL SWITCH W660 0006 SPILL SWITCH ACCESSORIES OPTIONS GDS28 GS28 W690 0001 MILLI...

Страница 21: ...standing Main burner is in OFF position turn on all gas appliances and see if pilot flame flutters diminishes or extinguishes especially when main burner ig nites Monitor supply pressure check if supp...

Страница 22: ...location of storm collars Incorrect installation Carbon is being de posited on glass logs or combustion chamber surfaces Flame is impinging on the logs or combustion chamber check that the logs are co...

Страница 23: ...23 W415 0153 A 10 29 01 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Страница 24: ...24 W415 0153 A 10 29 01 NOTES...

Отзывы: