EN
W415-1767 / F / 07.20.18
17
electrical information
A.
Remove the cover plate by removing the 3 screws
(Fig. 1)
. Set screws aside.
BLACK
WHITE
BLACK(L1)
WHITE (N)
GREEN
GREEN
(L1)
(N)
(G)
BLUE (N1)
GRAY (N2)
RED (L2)
(G)
120V
YELLOW
(JUMPER)
TERMINAL BLOCK
3.3
120V hard wire connection
A.
Loosen the securing screw from the terminal block to remove the cord from the terminal block.
KEEP 2
WIRE JUMPERS IN THE TERMINAL BLOCK.
B.
Add a strain relief and feed the supply wires through the 7/8” (22mm) hole from the terminal block.
C.
Insert White (N) wire from power supply to the designated (N) slots in the terminal block. Secure by
tightening the screws on the (N) slots.
ENSURE JUMPER WIRES ARE SECURED.
D.
Run Black (L1) and Green (G) wires from the power supply to designated slots on the terminal block.
E.
Re-install cover plate.
Fig. 1
Leave enough wiring so that the appliance can be removed from the enclosure without disconnecting the
appliance from the power supply.
note:
Front Side of Appliance
Terminal Block
Fig. 2
B.
Remove the terminal block from the power cord assembly by removing the 2 screws
(Fig. 2)
. Set terminal
block and screws aside; discard power cord assembly.
C.
Hard wire appliance (see “120V hard wire connection” and
“240V hard wire connection” sections).
D.
Install the small end of the strain relief into the new cover
plate (supplied) using the screws previously removed in
step A
(Fig. 3)
.
Power Cord
Assembly
Fig. 3
Strain Relief
Bushing