electrical information
3.2 hard wiring installation
Hard Wiring Connection
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and wire the
appliance directly to the household wiring. The wire and power supply breaker must rated for 120V minimum 15
amps.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In the
absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
There are 6 wires from the appliance junction box: 1 green (G), 1 white (N), 1 blue (N1), 1 gray (N2), 1 black (L1),
and 1 red (L2).
note:
CONNECT TO
120V POWER
SUPPLY MIN.
15AMPS
GREEN
BLACK
WHITE
FIREPLACE
JUNCTION
NEUTRAL
L1
GROUND
240V HARD WIRING INSTALLATION
CONNECT TO
240V POWER
SUPPLY MIN.
15AMPS
RED
L2
L2
L1
N
N1
BLUE
N2
G
GRAY
TERMINAL BLOCK
GREEN
BLACK
WHITE
FIREPLACE
JUNCTION
NEUTRAL
L1
GROUND
120V HARD WIRING INSTALLATION
RED
L2
L1
N
N1
BLUE
N2
G
GRAY
TERMINAL BLOCK
JUMPERS
W385-2232
W385-2233
!
WARNING
•
Turn off the appliance completely and let cool before servicing. Only a qualifi ed service person should service
and repair this electric appliance.
W385-2232
W385-2233