26
W415-1107 / 07.24.12
IMPORTANT:
The
requires a minimum inside enclosure height of 96” measured from the bottom of the appliance.
For temperature requirements, this area must be left unobstructed.
It is recommended that the enclosure be ventilated at the top and bottom to circulate the hot air with 2, 40”
square openings.
* See Venting Section
** Within the appliance enclosure a 9” clearance between the vertical vent run and the combustible materials
on the front facing of the enclosure is required. Similarly, a 5” clearance to combustible materials from the top
of the horizontal vent run is required. All other clearances within the enclosure, including where the vent pipe
exits the enclosure are subject to 2” for horizontal and 1” for vertical.
5.2 MINIMUM ENCLOSURE CLEARANCES
!
WARNING
RISK OF FIRE!
THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT COVER
THE APPLIANCE OPENING.
2”
2”
96”
46 1/2”
9”**
86 1/2”
MINIMUM
PLUS
RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
BRICK
COMBUSTIBLE
NON-
COMBUSTIBLE
0” IF NON-
COMBUSTIBLE FINISH-
ING IS USED SUCH AS
BRICK AND STONE
TOP OF
FIREPLACE
TOP OF
FIREPLACE
OPENING
5”**
1”