venting requirements
90°
V
1
V
2
H
1
H
2
90°
90°
H
3
45°
18.2_3B
Example:
V
1
= 1.5 FT (0.5m)
V
2
= 5 FT (1.5m)
V
T
= V
1
+ V
2
= 1.5FT (0.5m)+ 5FT (1.5m) = 6.5 FT (2m)
H
1
= 1 FT (0.3m)
H
2
= 1 FT (0.3m)
H
3
= 10.75 FT (3.3m)
H
R
= H
1
+ H
2
+ H
3
= 1FT (0.3m) + 1FT (0.3m) + 10.75FT (3.3m) = 12.75FT (3.9m)
H
O
= .03 (three 90° one 45° elbow - 90°)
= .03 (270° + 45° - 90°) = 6.75 FT (2.1m)
H
T
= H
R
+ H
O
= 12.75FT (3.9m) + 6.75FT (2.1m) = 19.5 FT (5.9m)
H
T
+ V
T
= 19.5FT (5.9m) + 6.5FT (2m) = 26 FT (7.9m)
Formula 1:
H
T
< 3 V
T
3 V
T
= 3FT (0.9m) x 6.5FT (2m) = 19.5FT (5.9m)
19.5FT (5.9m) = 19.5FT (5.9m)
Formula 2:
H
T
+ V
T
< 40 FT (12.2m)
26 FT (7.9m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
A.
Remove the safety barrier and glass front, refer to "safety
barrier & door removal/installation" section.
B.
Remove the contents from the firebox and set aside, you will
need the exhaust flue collar from the top of the log carton.
C.
To ease assembly, remove the four hex head screws
securing the deflector from inside the top front of the firebox,
refer to Figure 1.
D.
Place the gasket (provided) over the 4" (102mm) flue collar
assembly and bend along perforation.
E.
From inside the firebox, insert the 4" (102mm) flue collar through the back
of the firebox. Install the rear exit shield onto the 4" (102mm) flue collar, see
"rear exit shield" section for installation instructions.
F.
Secure the flue collar assembly, gasket and rear exit shield using the four hex
head 3/8" thread cutting screws, refer to Figure 2.
G.
Reattach the deflector using the four screws and
install the log set, glass door and safety barrier.
H.
Install the 7" collar assembly, complete with
gasket, onto the rear panel around the 4"
(101.6mm) collar with the screws provided (FIG 3).
Fig. 2
DEFLECTOR
DÉFLECTEUR
Fig. 1
2.10 rear exit
• Failure to create a seal to the firebox with the exhaust collar assembly will cause the appliance to function
improperly and can cause injury or property damage.
!
WARNING
Do not overtighten. The gasket needs only to be
snug against the firebox.
note:
Fig. 3
INTAKE COLLAR
ASSEMBLY
GASKET
JOINT
D’ÉTANCHÉITÉ
COLLET
D’ÉVACUATION
Содержание Ascent X 36
Страница 73: ...EN W415 2354 B 12 09 20 73 notes 29 1...
Страница 146: ...W415 2354 B 12 09 20 146 FR notes 29 1...
Страница 147: ...W415 2354 B 12 09 20 147 notes FR 29 1...