background image

To perform designated “Hold-Down” Func-

tions, selected key must be held down for
about 2 seconds, until sounder beeps. Note:
Those functions identified by an asterisk ()
have secondary utility functions for installer’s
use only. Do not attempt to access these func-
tions within 10 seconds after disarming.

Key [1]: TEST

Momentarily sounds the burglar alarm. If no

alarm is heard, or if it is weak, the battery may
need replacing. Make this test weekly. (To per-
form this function, hold down Key [1] until
alarm sounds.)

Key [2]: DISPLAY BYPASS

Numerically displays all zones that have

been bypassed using Key [S]. To perform this
function, hold down Key [2] until the sounder
beeps, and continue to hold it down until all
zones have been displayed.

Key [3]: DISPLAY STATUS

Numerically displays all zones that are in

“trouble”. To perform this function, hold down
Key [3] until the sounder beeps, and continue
to hold it down until all zones have been dis-
played.

Key [4]: INSTANT PROTECTION*

Cancels entry delay period when arming.

The delay is restored after you disarm the sys-
tem. To perform this function, hold down Key

[4] until the sounder beeps.

Key [5]: CHIME*  (Chime Zone(s): _________)

This will enable a feature that sounds a

“chime” (beep) at the keypad each time a pro-
grammed zone (Entry Zone, in the MA854) is
opened. The Chime Mode functions when the
alarm system is disarmed (off), but it will al-
ways operate on a Never-Arm Zone (see
GLOSSARY). To disable the chime feature,
hold down Key [5] again (until sounder
beeps).

Key [6]: TELCO TEST*
 
(Optional; Enabled?   YES

 

 NO)

Pressing the key tests your phone lines (the

sounder will start to pulse). If the line is good,
the pulsing will stop: if not, a steady tone will
sound. (To perform this function, hold down
Key [6] until sounder beeps.) Reset the
sounder using Key [9]. Call for service, if nec-
essary.

Key [7]: FAULT FIND 

For installer’s use only; holding down Reset

Key [9] or arming the panel will cancel the
Fault-Find Mode.

Key [8]: PROGRAM

(Alarm functions are disabled while in the

Program Mode.) Allows you to enter the Pro-
gram Mode, where you can program up to 5
personal User Codes (up to 4 in the MA854),

including a Service Code (MA1008 and
MA1010 only, optional). Refer to SELECTING
AND PROGRAMMING YOUR CODES
 for
more information. (To perform this function,
hold down Key [8] until sounder beeps.)

Key [9]: RESET

Resets any sounder indication, system-

trouble indication, Day-Zone indication (in
MA1008 and MA1010, may be programmed to
reset Day-Zone condition), and Fault-Find
Mode. After an alarm occurs and the system
is disarmed, the numerical display will still in-
dicate which non-24-Hour Zone(s) caused the
alarm. Key [9] will clear the display. (To per-
form this function, hold down Key [9] until
sounder beeps.)

Key [S]: ALARM HISTORY

This will flash the red ARMED/ALARM light

to indicate the last alarm condition. The nu-
merical display will indicate the zones vio-
lated. History is not lost when the system is
rearmed; the previous alarm history will re-
main in alarm memory until automatically re-
set by a new alarm condition. To perform this
function, hold down Key [S] until the sounder
beeps, then continue to hold it down until all
information has been displayed.

HOLD-DOWN FUNCTIONS

7

Содержание RP1054D KEYPAD

Страница 1: ...OPERATING GUIDE FOR YOUR RP1054D KEYPAD Napco 1992 DESIGN PATS PENDING ...

Страница 2: ...itu ation Your system has been carefully designed and engineered to the highest industry stand ards To assure optimum safety and security familiarize yourself with this equipment Peri odically check its condition and state of readi ness by testing it at least once a week in both the ac battery and battery only modes ask your installer how to make these tests TABLE OF CONTENTS Section Page CENTRAL ...

Страница 3: ...ng and Closing Reporting Notifies the central station every time the system is dis armed and armed Each user opening or clos ing can be identified by his code Telephone Line Test Programmed Op tion To check your telephone connection with the central station hold down Key 6 Af ter the beep sounds a pulse tone will be heard from the keypad sounder If the phone line is good the sound will silence in ...

Страница 4: ...cator Reports intrusions and emergencies directly to the central station over telephone lines Control Panel The brain of the system it controls all system functions Disarm To turn the system off by entering a User Code at the keypad Exit Entry Delay A programmed time that lets you exit and enter your premises without setting off an alarm after the system is armed Instant Protection Arming without ...

Страница 5: ... corrected at which time the display will be cleared and the Day Zone re enabled Exit Entry Zone Provides exit and entry delays to permit arming and disarming without causing an alarm Exit Entry Follower Zone For interior zones Ignores detection during exit delay ignores detection during entry delay only if re entry takes place through the normal exit entry door Fire Zone A zone that provides audi...

Страница 6: ...hts Flashing slowly with digit displayed ex cept with MA854 and early MA1008 MA1010 panels System trouble see SETTING THE ALARM WHEN LEAVING Flashing rapidly with pulsing sounder User Program Mode press S twice to exit FIRE TROUBLE Light On Fire Zone in alarm condition Flashing Fire Zone in trouble condition Keypad Sounder Steady Tone with P displayed a priority condition exists Steady Tone when e...

Страница 7: ...ey 6 TELCO TEST Optional Enabled YES NO Pressing the key tests your phone lines the sounder will start to pulse If the line is good the pulsing will stop if not a steady tone will sound To perform this function hold down Key 6 until sounder beeps Reset the sounder using Key 9 Call for service if nec essary Key 7 FAULT FIND For installer s use only holding down Reset Key 9 or arming the panel will ...

Страница 8: ...y your in staller Selecting Your Codes After your alarm specialist installs your sys tem he will give you a User Program Code and show you how to program your User Codes For optimum security do not select obvious combinations such as consecutive numbers 1 2 3 4 repetitive numbers 2 2 2 2 your street or telephone number birth date etc for any user code A code of at least three digits is required in...

Страница 9: ...ld never be shown how to bypass a zone Group Bypass Zones are a group of zones that can all be manually bypassed simultaneously by simply pressing Key S twice See PROTECTING YOURSELF WHILE ON THE PREMISES By passing Interior Zones You will not be able to arm your system if a a Priority Zone is in trouble b a Day Zone numerical display is still flashing or c the first three keypad lights are flashi...

Страница 10: ...er will be displayed even after you disarm To reset the display hold down Key 9 When the system is disarmed the red ARMED ALARM light will go off and the green light will come on or flash if a zone is in trouble If an alarm occurred on a 24 Hour Zone there will be no indication at the keypad how ever an alarm condition will be recorded by Alarm History see Key S Bypass Alarm History Ambush Code If...

Страница 11: ...ill come on whenever you bypass one or more zones En ter your code to arm remaining zones the green light will go off and the red ARMED ALARM light will come on The yellow light will go off the next time you disarm indi cating that the bypassed zones are no longer bypassed The BYPASS light does not come on when zones are auto bypassed unless pro grammed otherwise by your alarm specialist To review...

Страница 12: ...the sounder will pulse after a 10 second delay To silence the sounder hold down Key 9 The light will continue to flash to indicate the trouble After the trouble is repaired hold down Key 9 again until the beep sounds the keypad will reset after a brief delay and the light will go off Resetting After An Alarm The fire alarm may be reset by holding down Key 9 for 2 seconds then arming and disarming ...

Отзывы: