Arming With Zones Bypassed

Your alarm specialist may have pro-

grammed one or more zones for Selective By-
pass, that is, they may be removable from the
system. Since a bypassed zone cannot cause
an alarm, you may wish to use this feature to
turn off the interior areas while armed and
keep your perimeter zones (windows, doors,
etc.) active.

Press the bypass button (Key [S]), then the

number of the zone you wish to bypass.
Check the green STATUS light to be sure that
no zone is in trouble, then enter your arming
code to arm.

To verify which zones have been bypassed,

hold down Key [2] until all zones have been
displayed.

Bypassing Interior Zones

Your installer may have also selected all in-

terior zones to be Group Bypass Zones (not
for UL installations). Bypass these zones all at

the same time by simply pressing Key [S]
twice. The yellow BYPASS light will come on
whenever you bypass one or more zones. En-
ter your code to arm remaining zones; the
green light will go off and the red
ARMED/ALARM light will come on. The yellow
light will go off the next time you disarm, indi-
cating that the bypassed zones are no longer
bypassed. (The BYPASS light does not come
on when zones are auto-bypassed (unless pro-
grammed otherwise by your alarm specialist.)
To review which zones have been bypassed,
hold down Key [2] until all bypassed zones
have been displayed.

Arming With Instant Protection

Holding down Key [4] (until beep sounds)

will cancel the entry delay on the exit/entry
zones when arming. The red ARMED/ALARM
light will flash rapidly to indicate this condi-
tion. If someone enters through an Exit/Entry
Zone, an alarm will sound immediately.

Panic Alarm

(Keypad Panic Disabled? 

 

YES

 

 

NO)

To activate a Panic Alarm, press Keys [*]

and [# ] at the same time. This feature may
have been programmed to send a silent alarm
to a central station, activate an audible alarm,
or both.

PROTECTING YOURSELF WHILE ON THE PREMISES

11

Содержание RP1054D KEYPAD

Страница 1: ...OPERATING GUIDE FOR YOUR RP1054D KEYPAD Napco 1992 DESIGN PATS PENDING ...

Страница 2: ...itu ation Your system has been carefully designed and engineered to the highest industry stand ards To assure optimum safety and security familiarize yourself with this equipment Peri odically check its condition and state of readi ness by testing it at least once a week in both the ac battery and battery only modes ask your installer how to make these tests TABLE OF CONTENTS Section Page CENTRAL ...

Страница 3: ...ng and Closing Reporting Notifies the central station every time the system is dis armed and armed Each user opening or clos ing can be identified by his code Telephone Line Test Programmed Op tion To check your telephone connection with the central station hold down Key 6 Af ter the beep sounds a pulse tone will be heard from the keypad sounder If the phone line is good the sound will silence in ...

Страница 4: ...cator Reports intrusions and emergencies directly to the central station over telephone lines Control Panel The brain of the system it controls all system functions Disarm To turn the system off by entering a User Code at the keypad Exit Entry Delay A programmed time that lets you exit and enter your premises without setting off an alarm after the system is armed Instant Protection Arming without ...

Страница 5: ... corrected at which time the display will be cleared and the Day Zone re enabled Exit Entry Zone Provides exit and entry delays to permit arming and disarming without causing an alarm Exit Entry Follower Zone For interior zones Ignores detection during exit delay ignores detection during entry delay only if re entry takes place through the normal exit entry door Fire Zone A zone that provides audi...

Страница 6: ...hts Flashing slowly with digit displayed ex cept with MA854 and early MA1008 MA1010 panels System trouble see SETTING THE ALARM WHEN LEAVING Flashing rapidly with pulsing sounder User Program Mode press S twice to exit FIRE TROUBLE Light On Fire Zone in alarm condition Flashing Fire Zone in trouble condition Keypad Sounder Steady Tone with P displayed a priority condition exists Steady Tone when e...

Страница 7: ...ey 6 TELCO TEST Optional Enabled YES NO Pressing the key tests your phone lines the sounder will start to pulse If the line is good the pulsing will stop if not a steady tone will sound To perform this function hold down Key 6 until sounder beeps Reset the sounder using Key 9 Call for service if nec essary Key 7 FAULT FIND For installer s use only holding down Reset Key 9 or arming the panel will ...

Страница 8: ...y your in staller Selecting Your Codes After your alarm specialist installs your sys tem he will give you a User Program Code and show you how to program your User Codes For optimum security do not select obvious combinations such as consecutive numbers 1 2 3 4 repetitive numbers 2 2 2 2 your street or telephone number birth date etc for any user code A code of at least three digits is required in...

Страница 9: ...ld never be shown how to bypass a zone Group Bypass Zones are a group of zones that can all be manually bypassed simultaneously by simply pressing Key S twice See PROTECTING YOURSELF WHILE ON THE PREMISES By passing Interior Zones You will not be able to arm your system if a a Priority Zone is in trouble b a Day Zone numerical display is still flashing or c the first three keypad lights are flashi...

Страница 10: ...er will be displayed even after you disarm To reset the display hold down Key 9 When the system is disarmed the red ARMED ALARM light will go off and the green light will come on or flash if a zone is in trouble If an alarm occurred on a 24 Hour Zone there will be no indication at the keypad how ever an alarm condition will be recorded by Alarm History see Key S Bypass Alarm History Ambush Code If...

Страница 11: ...ill come on whenever you bypass one or more zones En ter your code to arm remaining zones the green light will go off and the red ARMED ALARM light will come on The yellow light will go off the next time you disarm indi cating that the bypassed zones are no longer bypassed The BYPASS light does not come on when zones are auto bypassed unless pro grammed otherwise by your alarm specialist To review...

Страница 12: ...the sounder will pulse after a 10 second delay To silence the sounder hold down Key 9 The light will continue to flash to indicate the trouble After the trouble is repaired hold down Key 9 again until the beep sounds the keypad will reset after a brief delay and the light will go off Resetting After An Alarm The fire alarm may be reset by holding down Key 9 for 2 seconds then arming and disarming ...

Отзывы: