Trouble. An open door, window, or other

problem on a zone that may prevent arming.

User Program Code. A code (up to 6 digits)

required to enter the Program Mode in order
to program or change Arm/Disarm Codes.

Watch Mode (MA1008 and MA1010 only).

Turns all Day Zones on and off simultaneously
by pressing Key [S] twice. (Optional.)

Zones. Independent circuits that protect

specific areas of the premises:

Auto-Bypass Zone: A zone that will auto-
matically be bypassed from the system if
in trouble (faulty) when the system is
armed. (Not available in UL installations.)

Burglary Zone: Detects intrusion.

Day Zone: A zone programmed to cause
visual and audible indication at the keypad
when it is in trouble while disarmed. This
feature is generally used to detect a prob-
lem, such as a break in a window foil, dur-
ing the day. If a Day Zone is open, the
green STATUS light will flash, the sounder
will pulse, and the numerical display will in-
dicate the zone. Hold down Key [9] to si-

lence the sounder and clear the display.
Arm and disarm the panel to re-enable the
Day Zone. (In the MA1008 or MA1010, this
feature may have been programmed so
that Key [9] will turn off only the sounder;
the display will continue to indicate the
open zone until the zone is corrected, at
which time the display will be cleared and
the Day Zone re-enabled.)

Exit/Entry Zone: Provides exit and entry
delays to permit arming and disarming
without causing an alarm.

Exit/Entry Follower Zone: For interior
zones. Ignores detection during exit delay;
ignores detection during entry delay only if
re-entry takes place through the normal
exit/entry door.

Fire Zone: A zone that provides audible
and visual indication at the keypad in the
event of a fire alarm or trouble condition.
The Fire Zone is active 24 hours a day.

Group-Bypass Zones: Circuits within the
premises, usually including space-protec-
tion devices, interior doors, etc. (but not ex-

terior doors or windows) that can all be by-
passed simultaneously by pressing Key [S]
twice. (Not available in UL installations.)

Never-Arm Zone: (MA1008 and MA1010
only): A zone that will remain disarmed,
even when the rest of the system is armed.
If Chime is programmed, the keypad will
sound while armed or disarmed. This fea-
ture may be used as a driveway monitor,
pool alert, etc.

Priority Zone: A zone that prevents arming
if in trouble.

Priority Zone with Bypass: A Priority Zone
that can be bypassed by pressing Reset
Key [9] then entering your Arm/Disarm
Code.

Selective-Bypass Zone: A zone that can
be individually bypassed by pressing Key
[S] followed by the zone number.

24-Hour Zone: A zone that is armed and
ready at all times to respond to an emer-
gency situation.

GLOSSARY

5

Содержание RP1054D KEYPAD

Страница 1: ...OPERATING GUIDE FOR YOUR RP1054D KEYPAD Napco 1992 DESIGN PATS PENDING ...

Страница 2: ...itu ation Your system has been carefully designed and engineered to the highest industry stand ards To assure optimum safety and security familiarize yourself with this equipment Peri odically check its condition and state of readi ness by testing it at least once a week in both the ac battery and battery only modes ask your installer how to make these tests TABLE OF CONTENTS Section Page CENTRAL ...

Страница 3: ...ng and Closing Reporting Notifies the central station every time the system is dis armed and armed Each user opening or clos ing can be identified by his code Telephone Line Test Programmed Op tion To check your telephone connection with the central station hold down Key 6 Af ter the beep sounds a pulse tone will be heard from the keypad sounder If the phone line is good the sound will silence in ...

Страница 4: ...cator Reports intrusions and emergencies directly to the central station over telephone lines Control Panel The brain of the system it controls all system functions Disarm To turn the system off by entering a User Code at the keypad Exit Entry Delay A programmed time that lets you exit and enter your premises without setting off an alarm after the system is armed Instant Protection Arming without ...

Страница 5: ... corrected at which time the display will be cleared and the Day Zone re enabled Exit Entry Zone Provides exit and entry delays to permit arming and disarming without causing an alarm Exit Entry Follower Zone For interior zones Ignores detection during exit delay ignores detection during entry delay only if re entry takes place through the normal exit entry door Fire Zone A zone that provides audi...

Страница 6: ...hts Flashing slowly with digit displayed ex cept with MA854 and early MA1008 MA1010 panels System trouble see SETTING THE ALARM WHEN LEAVING Flashing rapidly with pulsing sounder User Program Mode press S twice to exit FIRE TROUBLE Light On Fire Zone in alarm condition Flashing Fire Zone in trouble condition Keypad Sounder Steady Tone with P displayed a priority condition exists Steady Tone when e...

Страница 7: ...ey 6 TELCO TEST Optional Enabled YES NO Pressing the key tests your phone lines the sounder will start to pulse If the line is good the pulsing will stop if not a steady tone will sound To perform this function hold down Key 6 until sounder beeps Reset the sounder using Key 9 Call for service if nec essary Key 7 FAULT FIND For installer s use only holding down Reset Key 9 or arming the panel will ...

Страница 8: ...y your in staller Selecting Your Codes After your alarm specialist installs your sys tem he will give you a User Program Code and show you how to program your User Codes For optimum security do not select obvious combinations such as consecutive numbers 1 2 3 4 repetitive numbers 2 2 2 2 your street or telephone number birth date etc for any user code A code of at least three digits is required in...

Страница 9: ...ld never be shown how to bypass a zone Group Bypass Zones are a group of zones that can all be manually bypassed simultaneously by simply pressing Key S twice See PROTECTING YOURSELF WHILE ON THE PREMISES By passing Interior Zones You will not be able to arm your system if a a Priority Zone is in trouble b a Day Zone numerical display is still flashing or c the first three keypad lights are flashi...

Страница 10: ...er will be displayed even after you disarm To reset the display hold down Key 9 When the system is disarmed the red ARMED ALARM light will go off and the green light will come on or flash if a zone is in trouble If an alarm occurred on a 24 Hour Zone there will be no indication at the keypad how ever an alarm condition will be recorded by Alarm History see Key S Bypass Alarm History Ambush Code If...

Страница 11: ...ill come on whenever you bypass one or more zones En ter your code to arm remaining zones the green light will go off and the red ARMED ALARM light will come on The yellow light will go off the next time you disarm indi cating that the bypassed zones are no longer bypassed The BYPASS light does not come on when zones are auto bypassed unless pro grammed otherwise by your alarm specialist To review...

Страница 12: ...the sounder will pulse after a 10 second delay To silence the sounder hold down Key 9 The light will continue to flash to indicate the trouble After the trouble is repaired hold down Key 9 again until the beep sounds the keypad will reset after a brief delay and the light will go off Resetting After An Alarm The fire alarm may be reset by holding down Key 9 for 2 seconds then arming and disarming ...

Отзывы: