Trouble. An open door, window, or other
problem on a zone that may prevent arming.
User Program Code. A code (up to 6 digits)
required to enter the Program Mode in order
to program or change Arm/Disarm Codes.
Watch Mode (MA1008 and MA1010 only).
Turns all Day Zones on and off simultaneously
by pressing Key [S] twice. (Optional.)
Zones. Independent circuits that protect
specific areas of the premises:
•
Auto-Bypass Zone: A zone that will auto-
matically be bypassed from the system if
in trouble (faulty) when the system is
armed. (Not available in UL installations.)
•
Burglary Zone: Detects intrusion.
•
Day Zone: A zone programmed to cause
visual and audible indication at the keypad
when it is in trouble while disarmed. This
feature is generally used to detect a prob-
lem, such as a break in a window foil, dur-
ing the day. If a Day Zone is open, the
green STATUS light will flash, the sounder
will pulse, and the numerical display will in-
dicate the zone. Hold down Key [9] to si-
lence the sounder and clear the display.
Arm and disarm the panel to re-enable the
Day Zone. (In the MA1008 or MA1010, this
feature may have been programmed so
that Key [9] will turn off only the sounder;
the display will continue to indicate the
open zone until the zone is corrected, at
which time the display will be cleared and
the Day Zone re-enabled.)
•
Exit/Entry Zone: Provides exit and entry
delays to permit arming and disarming
without causing an alarm.
•
Exit/Entry Follower Zone: For interior
zones. Ignores detection during exit delay;
ignores detection during entry delay only if
re-entry takes place through the normal
exit/entry door.
•
Fire Zone: A zone that provides audible
and visual indication at the keypad in the
event of a fire alarm or trouble condition.
The Fire Zone is active 24 hours a day.
•
Group-Bypass Zones: Circuits within the
premises, usually including space-protec-
tion devices, interior doors, etc. (but not ex-
terior doors or windows) that can all be by-
passed simultaneously by pressing Key [S]
twice. (Not available in UL installations.)
•
Never-Arm Zone: (MA1008 and MA1010
only): A zone that will remain disarmed,
even when the rest of the system is armed.
If Chime is programmed, the keypad will
sound while armed or disarmed. This fea-
ture may be used as a driveway monitor,
pool alert, etc.
•
Priority Zone: A zone that prevents arming
if in trouble.
•
Priority Zone with Bypass: A Priority Zone
that can be bypassed by pressing Reset
Key [9] then entering your Arm/Disarm
Code.
•
Selective-Bypass Zone: A zone that can
be individually bypassed by pressing Key
[S] followed by the zone number.
•
24-Hour Zone: A zone that is armed and
ready at all times to respond to an emer-
gency situation.
GLOSSARY
5