background image

28 

 

NAPCO SECURITY SYSTEMS, INC. (NAPCO) war-
rants its products to be free from manufacturing defects 
in materials and workmanship for 

thirty-six months

 fol-

lowing the date of manufacture. NAPCO will, within said 
period, at its option, repair or replace any product failing 
to operate correctly without charge to the original pur-
chaser or user. 
 
This warranty shall not apply to any equipment, or any 
part thereof, which has been repaired by others, improp-
erly installed, improperly used, abused, altered, dam-
aged, subjected to acts of God, or on which any serial 
numbers have been altered, defaced or removed. Seller 
will not be responsible for any dismantling or reinstalla-
tion charges. 
   
THERE ARE NO WARRANTIES, EXPRESS OR IM-
PLIED, WHICH EXTEND BEYOND THE DESCRIP-
TION ON THE FACE HEREOF. THERE IS NO EX-
PRESS OR IMPLIED WARRANTY OF MERCHANT-
ABILITY OR A WARRANTY OF FITNESS FOR A PAR-
TICULAR PURPOSE. ADDITIONALLY, THIS WAR-
RANTY IS IN LIEU OF ALL OTHER OBLIGATIONS OR 
LIABILITIES ON THE PART OF NAPCO. 
   
Any action for breach of warranty, including but not lim-
ited to any implied warranty of merchantability, must be 
brought within the six months following the end of the 
warranty period.  
   
IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE 
FOR ANY CONSEQUENTIAL OR INCIDENTAL DAM-
AGES FOR BREACH OF THIS OR ANY OTHER WAR-
RANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS 
OR DAMAGE IS CAUSED BY THE SELLER'S OWN 
NEGLIGENCE OR FAULT. 
   
In case of defect, contact the security professional who 
installed and maintains your security system. In order to 
exercise the warranty, the product must be returned by 
the security professional, shipping costs prepaid and 
insured to NAPCO. After repair or replacement, NAPCO 
assumes the cost of returning products under warranty. 
NAPCO shall have no obligation under this warranty, or 
otherwise, if the product has been repaired by others, 
improperly installed, improperly used, abused, altered, 
damaged, subjected to accident, nuisance, flood, fire or 
acts of God, or on which any serial numbers have been 
altered, defaced or removed. NAPCO will not be re-
sponsible for any dismantling, reassembly or reinstalla-
tion charges. 
 
This warranty contains the entire warranty. It is the sole 
warranty and any prior agreements or representations, 
whether oral or written, are either merged herein or are 
expressly cancelled. NAPCO neither assumes, nor au-

thorizes any other person purporting to act on its behalf 
to modify, to change, or to assume for it, any other war-
ranty or liability concerning its products. 
In no event shall NAPCO be liable for an amount in ex-
cess of NAPCO's original selling price of the product, for 
any loss or damage, whether direct, indirect, incidental, 
consequential, or otherwise arising out of any failure of 
the product. Seller's warranty, as hereinabove set forth, 
shall not be enlarged, diminished or affected by and no 
obligation or liability shall arise or grow out of Seller's 
rendering of technical advice or service in connection 
with Buyer's order of the goods furnished hereunder. 
   
NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM 
BE COMPLETELY TESTED WEEKLY. 
   

Warning: 

Despite frequent testing, and due to, but not 

limited to, any or all of the following; criminal tampering, 
electrical or communications disruption, it is possible for 
the system to fail to perform as expected. NAPCO does 
not represent that the product/system may not be com-
promised or circumvented; or that the product or system 
will prevent any personal injury or property loss by bur-
glary, robbery, fire or otherwise; nor that the product or 
system will in all cases provide adequate warning or 
protection. A properly installed and maintained alarm 
may only reduce risk of burglary, robbery, fire or other-
wise but it is not insurance or a guarantee that these 
events will not occur. CONSEQUENTLY, SELLER 
SHALL HAVE NO LIABILITY FOR ANY PERSONAL 
INJURY, PROPERTY DAMAGE, OR OTHER LOSS 
BASED ON A CLAIM THE PRODUCT FAILED TO 
GIVE WARNING. Therefore, the installer should in turn 
advise the consumer to take any and all precautions for 
his or her safety including, but not limited to, fleeing the 
premises and calling police or fire department, in order 
to mitigate the possibilities of harm and/or damage.  
 
NAPCO is not an insurer of either the property or safety 
of the user's family or employees, and limits its liability 
for any loss or damage including incidental or conse-
quential damages to NAPCO's original selling price of 
the product regardless of the cause of such loss or dam-
age. 
   
Some states do not allow limitations on how long an im-
plied warranty lasts or do not allow the exclusion or limi-
tation of incidental or consequential damages, or differ-
entiate in their treatment of limitations of liability for ordi-
nary or gross negligence, so the above limitations or ex-
clusions may not apply to you. This Warranty gives you 
specific legal rights and you may also have other rights 
which vary from state to state.       

 

NAPCO LIMITED WARRANTY 

Содержание Net.Link NL-RCV-RMPCUL

Страница 1: ...I1491A 5 07 Installing Programming and Using the NAPCO Net Link NL RCV RMPCUL Central Station Alarm Receiver TM R 333 Bayview Avenue Amityville New York 11701 For Sales and Repairs 800 645 9445 For Te...

Страница 2: ...17 Net Link Service Application Quick Access Buttons 18 Net Link Service Application Main Menu 18 Using the Service Application 19 24 Appendix A 25 Appendix B 26 NAPCO LIMITED WARRANTY 28 Table of Con...

Страница 3: ...lation Requirements The NL RCV RMPCUL Receiver complies with part 15 of the FCC rules THE FOLLOWING STATEMENT IS REQUIRED BY THE FCC This equipment generates and uses radio frequency energy and if not...

Страница 4: ...ed to the front panel of each Net Link Receiver housing Each keypad features an LCD with two rows of 16 characters each and a 0 9 numbered keypad that includes several special function buttons for vie...

Страница 5: ...the key to the right to open are several switches and lights from top to bottom as follows Reset Not used Red LED Lights during hard drive activity Green LED Lights when system is powered on Keyboard...

Страница 6: ...er using a standard 36 pin Centronics cable LAN Card LAN1 Primary connection to the Net Link Receiver and must be connected to the router LAN2 Interlink connection RJ 45 crossover cable e g NAPCO part...

Страница 7: ...tallation Diagram below each con nection is numbered in the diagram All connections are made at the rear of the Receiver INSTALLATION DIAGRAM Refer to page 6 for a description of the Receiver rear hou...

Страница 8: ...ackup configuration skip this step The Hot Backup Receiver is an optional component thus the Active Receiver can be in use for any amount of time before a Hot Backup Receiver is added to provide redun...

Страница 9: ...desktop shortcut and the Net Link Service Application Log On screen appears As shown in the image below the default User Name is Default Note There is no password associated with this User Name so jus...

Страница 10: ...s not require this field it is suggested to use the last 4 digits of the MAC Address Account Name An alphanumeric field used by the dealer to reference Account information Set Account Active Must be c...

Страница 11: ...the num ber as required Automation Type Currently only the Sur Gard SG SLR Single Line Receiver Contact ID protocol is used for host communication See Appendix B on page 26 for more information ComPo...

Страница 12: ...use CLEAR Button Press to silence audible Also exits without taking action while in Menu View Press G and CLEAR to clear events and troubles from the LCD Display Numerical Keys 0 9 Used for data entry...

Страница 13: ...new event is received If the Automation Host Computer system fails the Re ceiver will automatically revert to Manual Mode and a System Trouble event will be logged and displayed For Manual Mode operat...

Страница 14: ...ates a new event R indicates a restoral The next three digits indicate the Contact ID Code 130 Burglary 110 Fire etc the next two digits identify the area number and the final three digits identify th...

Страница 15: ...a hardware failure will generate a system trouble SYSTEM INFO Net Link Version Displays the version of the Net Link software currently installed in the existing Receiver Keypad Version Displays the cu...

Страница 16: ...032 can be entered as 32 VIEW ACKED EVENTS Displays events acknowledged using the ACK ENT button via the keypad in Manual Mode Press NEXT or PRIOR to scroll acknowledged events Press G and CLEAR to re...

Страница 17: ...1 04 2006 02 17 27 PM 01 0036 E602 06 U Z 194 Fail to Check In 01 04 2006 Date MM DD YYYY 02 17 27 PM Time HH MM SS AM or PM 01 Ordinal number sequencing the events for each Subscriber ID 0036 Subscri...

Страница 18: ...e currently active Account The Net Link Service Application toolbar above contains the Quick Access buttons It may be helpful to open each screen on your computer as you read From left to right they a...

Страница 19: ...page 18 for a full listing of all button names and menu names in this main screen FILE MENU As displayed in the image below the File menu allows you to Exit the application and Log Off your User Name...

Страница 20: ...ow will appear for new control panel installations that have not yet sent any status packets File Edit Active Account Click File Edit Active Account or press CTRL E and the following Edit Account dial...

Страница 21: ...events click the file that corresponds to the correct date in question Note It may take several moments for the data to be loaded and displayed Although the events can be scrolled the events listed in...

Страница 22: ...g Enable User Check to enable and uncheck to disable existing users When unchecked user in formation User type password etc remains within the system but is disabled thus denying the user the ability...

Страница 23: ...is is also the same address to which the router was port forwarded This screen al lows the Virtual IP Address to be changed When finished click OK to save or click Cancel to exit without saving When s...

Страница 24: ...ttings and the date In the bottom half of the screen you can set the new region and synchronize the date and time of the Receiver with that of the Service Application PC Click the Select New Time Zone...

Страница 25: ...mbers to identify the system trouble 100 Hot Backup Off Line 102 LAN Network Failure 103 Keypad Failure 105 Virtual IP Address Conflict 110 System Fan Failure 111 Temperature High 112 Watch Dog Failed...

Страница 26: ...s at which point an error is displayed and the system will try to re establish communications until automation type is set to NONE or communications have been re established CONTACT ID PROTOCOL DESCRI...

Страница 27: ...27 NOTES...

Страница 28: ...erson purporting to act on its behalf to modify to change or to assume for it any other war ranty or liability concerning its products In no event shall NAPCO be liable for an amount in ex cess of NAP...

Отзывы: