Bypassing Interior Zones
Interior zones allow perimeter zones to be armed while part or all of the active interior remains disarmed. When the
button is pressed, the “
” reminder will come on. Pressing the
button within 10 seconds will bypass the selected
interior group without arming, otherwise Interior Bypass will time out and the system will revert to the regular disarmed
state. All zones designated for the selected interior group(s) will be bypassed simultaneously when the system is armed.
To silence an alarm, enter a valid User Code, then press the
button.
Should a burglary alarm occur, the red ARMED LED will flash, and the display will alternately read “
”, then the zones
violated. Disarm the panel; the display will read “
” and will continue to indicate the violated zones until the
button is pressed or the panel is armed once again.
The keypad can provide a wide assortment of utility functions as summarized in the Keypad Programming Modes. The
functions are displayed in a prompting “
” format. To skip a function, answer NO (press the
button); to select
and execute a function, answer YES (press the
button or the
button). The complete function list is provided here
in its normal displayed sequence. However, since not all functions are designed for all systems (or intended for all users),
only functions that are applicable and active are displayed. (For example, if no zones are bypassed, “
”
will not appear.) Furthermore, functions that are intended for use by the installer or servicer will not be displayed. Note:
Functions may be manually scrolled forward or backward using the
and the
buttons, respectively.
To return to normal keypad operation, press the
button. (The keypad will automatically return to its normal
operating mode if no activity is detected for longer than one minute.)
Note: (1) In all UL-listed applications and in high-security installations, only those users having valid codes can access the
Function Mode. (2) Due to space constraints, GEM-RP2ASe2 message displays are abbreviated.
Remember: (1) Functions that are not active, not programmed and/or not applicable to the user's authority level will be
suppressed and will not display. (2) Press NO (
button) to skip a function; press YES (
button) to execute it.
(3) The GEM-RP2ASe2 displays abbreviated messages that autoscroll.
ACTIVATE BELL TEST
Press YES (
button) to activate the burg relay output (while disarmed) for about 2 seconds. If the device does not
sound, it may be defective.
ACTIVATE CHIME
Press YES (
button) to sound a tone at the keypad when a Chime Zone is violated. The duration of the tone is
programmable. To turn off the Chime Mode, press YES (
button) at the DEACTIVATE CHIME function.
ACTIVATE FAULT FIND
This troubleshooting aid will help the installer locate swingers. When accessed, two things occur:
The loop response of each zone is set for the fastest response time.
Causing or repairing a fault activates the sounder for about 7 seconds.
Tapping and poking at suspect points, the installer can easily locate swingers by listening for the beep. This eliminates the
need of returning to the keypad to visually check after each attempt. Pressing the
button to restore normal
operation. Arming the system automatically cancels the Fault find Mode. Note: When testing wireless systems, the
keypad will not beep if the signal strength is less than 3, but the strength will still be displayed.
BA
SIC OPERA
T
ION