NAPCO Security Group
NAPCO Gemini C-Series Control Panel Programming Instructions--Volume 1
Page 52
Programming Instructions, Volume 1
PROGRAM THE DATA ENTRIES
1. Enter the panel's Dealer Security Code, then press
R
.
2. Answer NO to all questions until "
ACTIVATE PROGRAM Y/N
" is displayed; then press YES.
NOTE:
If you pass
"
ACTIVATE PROGRAM
", scroll backward using
A
.
3. Press
C
to enter the Address Program Mode. Address "
0000
" will display.
4. Press
2018
to access Address 2018.
The existing data will display and the cursor will ad-
vance to the data field.
5. Press
2457
. The numbers 2, 4, 5 and 7 will appear on the keypad display indicating the
zones activated.
6. Press
U
to save. Address 2018 is now programmed with "2, 4, 5 and 7".
7. Press
R
and enter another 4-digit address to continue programming--or--press
C
to exit and resume
normal keypad operation.
B) DECIMAL FORMAT
Settings such as Entry Delay and Exit Delay display and accept data in "decimal" format, as a 3 digit number. Data
is entered directly, by pressing keys 0 – 9, with the cursor automatically moving to the right upon each key press.
EXAMPLE: Entries with the GEMC-FK1 keypads:
Pr o g r am
A b o r t Del ay
t o b e 15 s ec o n d s .
DETERMINE THE DATA ENTRIES
Referring to SYSTEM DELAYS & TIMEOUTS in the Programming Worksheets that follow, the Abort Delay is locat-
ed at address 5306:
PROGRAM THE DATA ENTRIES
1. Enter the panel's Dealer Security Code, then press
R
.
2. Answer NO to all questions until "
ACTIVATE PROGRAM Y/N
" is displayed; then press YES.
NOTE:
If you pass
"
ACTIVATE PROGRAM
", scroll backward using
A
.
3. Press
C
to enter the Address Program Mode. Address "
0000
" will display.
4. Press
5306
to access Address 5306.
The existing data will display and the cursor will ad-
vance to the data field.
5. Press
015
. The numbers 015 will appear on the keypad display indicating the number of
5 3 0 6 - - - D
5 3 0 6 0 1 5 D
ZONES 1
8
ZONES 9
16
ZONE FEATURES
ADDR Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 ADDR Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Exit/Entry Follower
2018
6 7 8
2118
DATA ENTRY LOCATION:
Decimal Format
No time yet entered
Address
5306
"Abort
Delay"
DATA ENTRY LOCATION:
Decimal Format
Press
015
in order to set the
"Abort Delay" to 15 seconds. The "D" on the
right indicates "Decimal" format.
ADDRESS 5306
[Default = 000]
ABORT
DELAY
(sec.)
Address
5306
"Abort
Delay"