THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN CONTROL PANEL
FIRMWARE VERSION 85 OR LATER, AND REFLECTS THE FEATURES FOUND IN
PCD-WINDOWS QUICKLOADER DOWNLOAD SOFTWARE VERSION 6.3.2 OR GREATER.
NAPCO Security Technologies, Inc.,
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, call toll free: (800) 645-9445
For direct line to Technical Service, call toll free: (800) 645-9440
Internet:
http://www.napcosecurity.com
Warning:
The use of non-NAPCO wireless devices with this control panel has not been evaluated by UL and
voids the UL listing. In addition, the performance of these devices can not be guaranteed as compatible with NAP-
CO control panels.
For systems that include CO detectors, the system must be monitored by a central station.
DOCUMENT REVISION HISTORY
Date
Revision
Description of Changes
August 2010
WI1673-1
WI1673-2
Preliminary release (beta)
June 2012
WI1673C-1
WI1673C-2
New programming feature "Supervisory Alarm Auto Reset" (address 5325 Option 6), added to Programming
Instructions Volume 2 page 93 in place of previous feature "Enable Telephone Line-Fault Test" in table.
Added new features to existing table to page 92 of Volume 2 (new options 1-5) and updated indexes.
Removed Zone Features "Interior (Stay) Bypass", "Night Arming" from Volume 2 pages 79-90.
January 2011
WI1673A-1
WI1673A-2
Original release
June 2011
WI1673B-1
WI1673B-2
Added "Horn/Strobe Simultaneous Silence" to page 92 and updated indexes
Added "Keypad 1 Always Unlocked for User Functions" and "All Keypads Unlocked for Silence, Reset and
Supp." to pages 13, 17 and 92 and updated indexes
Added "Unattended Download Mode" to pages 11, 16 and 96 and updated indexes
Added "Disable Panel Error Check Required Mode" to pages 9, 12 and 93 and updated indexes
Removed "2nd Call Answering Machine Override"; added "Disable Panel Error Check Required Mode" in
address 5326 option 6 (page 93)
Added "Coded Cadence 4 Cycles only" to page 93 and updated indexes
Replaced "0" with "
●
" in RECEIVER FORMATS table (page 32).
Changed documentation Firmware version to 83A (page 2 and page 70)
December 2014
WI1673D-1
WI1673D-2
Added references for the new Carbon Monoxide detector to the Zone Options in Volume 2.
IMPORTANT NOTE
The Gemini C-Series combination Fire and Burglary control panels are normally programmed with the
GEMC-FK1
Fire keypad. However, the control panel can also operate as a "Burglary Only" panel (following the procedure de-
tailed in the section "
BASIC OPERATION
,
Burg-Only Systems
" ), and may be programmed with the GEMC-BK1
keypad. In programming mode, the key locations used to program with the
GEMC-BK1 keypad are identical to the GEMC-FK1 keypad, however only
the button
labels
are different. Compare the images of the two keypads on
the cover of this volume. Note that the GEMC-FK1 keypad buttons "
NEXT
",
"
PRIOR
", "
ACK.
" and "
SILENCE
" are labeled "
INTERIOR
", "
INSTANT
",
"
G
", and "
BYPASS
" on the GEMC-BK1 Burglary keypad, respectively.
These button equivalents are also expressed in the table at right:
GEMC-FK1
GEMC-BK1
NEXT
INTERIOR
PRIOR
INSTANT
ACK.
G
SILENCE
BYPASS