![NAPCO GEM-ACM1D Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/napco/gem-acm1d/gem-acm1d_installation-instructions-manual_705420015.webp)
15
DIRECT ADDRESS PROGRAMMING
ACM ZONE OPTIONS:
!
Enter the Zone numbers (in decimal 1-255 format) for each option in the table below. Press
U
or
D
to save.
NOTE:
Dark shaded data value box shows option not available.
Note:
The Area # for Door 1 is controlled by the ex-
isting Keypad Programming table (Address 2425 to 2439). The assigned area for Door #2 for each ACM must be en-
tered in the table below (addresses 2748, 2758, 2768 and 2778) and must not be left blank if Door 2 is to be used.
AC M Z O N E O P T I O N S ( AD D R E S S 2 7 4 0 - 2 7 7 9 )
Direct Address Programming allows you to go directly to the address locations (up to 4095) and change the data entries
manually in order to customize your control panel options. The data entry location accepts data in one of three formats: Bi-
nary, Decimal and Hexadecimal. For more information, see the GEM-X255 Programming Instructions (WI1092).
ACCESSING DIRECT ADDRESS PROGRAM MODE
1. Enter the panel's Dealer Security Code, then press
R
.
2. Answer NO to all questions until “
ACTIVATE PROGRAM Y/N
” is displayed; then press YES.
NOTE:
If you pass “
ACTIVATE PROGRAM
”,
scroll backward using
B
.
3. Press
C
to enter the Address Program Mode. Address "
0000
" will display.
4. Press the 4 digits of the address (listed below).
The existing data will display and the cursor will advance to the data field.
5. Program the address as required.
6. Press
U
to save.
7. Enter another 4-digit address to continue programming or press
C
to exit and resume normal keypad operation.
KEYPAD #1:
For ease of programming, it is recommended that a GEM-K1CA (Version 8) be used as Keypad #1.
(Regardless of which keypad is selected, all
new
keypads are configured as Keypad #1 out of the box). The instruc-
tions below are depicted using the GEM-K1CA keypad.
ACM1 Zone Options
Door 1
ADDR
Door 2
Door Contact
2740
2745
Forced Entry Zone
2741
2746
Door Ajar Zone
2742
2747
ADDR
Area # for Door 2
2748
Reserved
2743
2749
Reserved
2744
ACM3 Zone Options
Door 1
ADDR
Door 2
Door Contact
2750
2755
Forced Entry Zone
2751
2756
Door Ajar Zone
2752
2757
ADDR
Area # for Door 2
2758
Reserved
2753
2759
Reserved
2754
ACM2 Zone Options
Door 1
ADDR
Door 2
Door Contact
2760
2765
Forced Entry Zone
2761
2766
Door Ajar Zone
2762
2767
ADDR
Area # for Door 2
2768
Reserved
2763
2769
Reserved
2764
ACM4 Zone Options
Door 1
ADDR
Door 2
Door Contact
2770
2775
Forced Entry Zone
2771
2776
Door Ajar Zone
2772
2777
ADDR
Area # for Door 2
2778
Reserved
2773
2779
Reserved
2774