Connections and wiring
3.4.4 Power supply connection
Permissible operating voltage
The permissible operating voltage for the SMCI36 lies b12 and +72 V DC; it
must not exceed 75 V or fall below 10 V.
A charging capacitor with minimum 4700 µF (10000 µF) must be provided for the
operating voltage to prevent exceeding the permissible operating voltage (e.g. during
braking).
Danger of electrical overvoltage
Connect a charging capacitor with minimum 4700 µF!
Use charging capacitors Z-K4700 from Nanotec to a maximum operating voltage of
50 V only!
Connect a capacitor with 10000 µF for motors with flange size 86x86 (series ST8918)
or greater!
An operating voltage > 75 V will destroy the output stage!
Accidentally swapping the connections will destroy the output stage. See the data
sheet of the connected stepper motor.
Never disconnect the motor while operating voltage is applied!
Never
hot-unplug lines.
Connection diagram
Note:
Overall connection diagram, see Section 2 "Connecting and commissioning".
Accessories
Appropriate power packs and charging capacitors are available as accessories:
Designation Order
identifier
Power pack
NTS-xxV-yA
(xx=voltage, y=current)
Information on the selection of the required
power supply unit can be found in our FAQ on
www.nanotec.de.
Charging capacitor
Z-K4700 (to max. 50 V) or Z-K10000
Note:
Further information about accessories can be found on the Nanotec website:
www.nanotec.de
Issue: V 1.0