Installation proposal
Danger:
Installation or maintenance work can only be carried out by trained and qualified
staff who must follow the procedures of this manual and use proper safety and protection
equipment.
Danger:
Disconnect the electrical power supply as well as the air plant system before any
installation or maintenance works.
Danger:
Do not use the condensate drain in hazardous areas with potentially explosive
indoor or outdoor atmospheres. The condensate drain has not been engineered in
accordance with the ATEX standard.
Danger:
Only use pressure-proof installation materials! The feed line must be firmly fixed.
Outlet line: short pressure hose to pressure-proof pipe. Ensure that condensate cannot squirt
onto persons or objects.
Note:
Do not discharge the condensate into the environment: the condensate water may
contain pollutants. Comply with local regulations and legislation.
Procedure
1.
Connect the inlet fitting of the condensate drain to the condensate collection point required,
using the compliant equipment.
Do not use the condensate drain as a lever.
In order to facilitate the installation, the drain is supplied with the revolving Easy-Lock
connection with an O-ring.
2.
Connect the outlet hose fittings of the condensate drain to the condensate collection point,
using a rubber hose with a diameter of 10 to 12 mm.
Remarks
Instruction book
18
2920 7213 30