nano purification solutions.
17-110-0140
12. Dryer Operation
Electrical Connector
Figure 1.
Under no circumstances should external voltage/current be applied to pins 1 and 4,
damage to the controller will occur, negating the warranty.
• To set up for remote control eco mode.
Remove the link between pins 1 and 4 (3)
in the electrical connector plug. A zero volt
switching signal from the remote control needs
to be connected between pins 1 and 4 (4).
• When the connection is made, the dryer will
operate normally. If the connection is broken,
i.e. the purifier has been remotely switched off,
the dryer will stop cycling and go into standby
mode, displaying “STANDBY” on the display
once completed.
• Using remote stop / start ensures the correct
shut-down sequence is implemented.
Dryer Remote Stop/Start Control (if required)
Locate the electrical connector on the underside of the controller in the shroud.
8.1 6 Pin Electrical Connector Configuration
Links 1/4
Remote stop/start link
1.
2.
3.
4.
Links 2/3
General (no-volt) alarm output
Links 5/6 (-Ve/+Ve)
4-20mA Retransmission
(Optional - where fitted)
Содержание 3 series