11
© by NECTA VENDING SOLUTIONS SpA
0306 180-02
MAIN SWITCH
The power supply unit (see Fig. 28) is fitted with a
microswitch that, when opening the sliding compartment,
disconnects the power from the machine electrical sys-
tem,
except from the terminal board supporting the line
cable, the line fuses and from the same switch area.
Before removing the cover from these parts (indicated
with a specific plate) it is necessary to disconnect the
external switch.
The power supply can be reconnected, if necessary, by
inserting the special key supplied with the machine.
All operations which require the machine to be ener-
gised with the door open must be carried out by
qualified personnel who are aware of the specific risks
of such condition.
DISPENSING COMPARTMENT MANUAL
RELEASE
Some models are fitted with a lock device in the dispens-
ing compartment that is released through electric control
when a selection is made (see compartment lock param-
eters).
Should for any reason be necessary to open the compart-
ment without electric power, do as follows:
- remove the last tray;
- remove the anti-theft grille;
- manually operate the lock device.
INTERNAL COMPONENTS
The evaporator assembly mounted on the cabinet shelf
comprises two fans, the evaporator, the air duct and a
water retaining tray placed under the evaporator.
The C.P.U. board (central processing unit) fitted inside the
payment system compartment controls the different func-
tions of the vending machine.
Fig. 15
1 - Product dispensing compartment housing
2 - Cooling unit condenser
3 - Cooling unit evaporator
4 - Cold air flow grilles
5 - Removable grille cover
6 - Tray guides
7 - Removable payment system compartment
8 - C.P.U. board
9 - Coin mechanism support
10 - Product passage photocells
11 - Power supply unit
12 - Payment system compartment door switch
The cooling unit is located in the lower part of the cabinet.
When removing the cover of the last ventilation grille (see
Fig. 15) the air circulation ensures a uniform temperature
inside the refrigerated box, between 9° and 12° C.
When covering the ventilation grille, the temperature
inside the refrigerated box is differentiated between the
upper three trays (12°-16°C) and the lower three trays (8°-
10°C).
The cooling unit is defrosted automatically every 6 hours.
In any case, the timing is programmable.
The power supply unit, mounted in the lower section of the
cabinet, contains the relay card which activates the com-
pressor, the protection fuses and the switch on the pay-
ment system door.
Содержание Snakky
Страница 1: ...INSTALLATION USE AND MAINTENANCE MANUAL UK English Snakky DOC NO H 180U 02 EDITION 3 2003 06...
Страница 2: ......
Страница 63: ...SCHEMA ELETTRICO WIRING DIAGRAM MACCHINA MACHINE Snakky...
Страница 64: ...NECTA VENDING SOLUTIONS SpA Sx36901...
Страница 65: ...Snakky...
Страница 66: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 68: ......