© by NECTA VENDING SOLUTIONS SpA
53
Technician menu - Summary
0306 180-02
CONFIRM DATA/
CONFIRM FUNCTION
DELETE DATA/
EXIT FUNCTION
PREVIOUS FUNCTION/
DECREASE DATA UNIT (-1)
NEXT FUNCTION/
INCREASE DATA UNIT (+1)
TECH >4
Test
TECH >4.1
Test selection
TECH >4.2
Motor test
Wait please
Selection num.##
Selection num.##
Wait please
The selection number
changes automatically
TECH >4.3
Autotest
Confirm?
Keypad test
Keypad test
Press 1 button
#
When pressing the button,
the next button is presented
automatically
Confirm?
Temperature test
Temperature test
Temp. = 12.2 °C
Confirm?
Buzzer test
Buzzer test
Working...
Emission of a series of
sounds
Confirm?
Compressor test
Compressor test
ON/OFF
OFF
ON
Confirm?
Selection test
Wait please
Selection num.##
All selections are activated in
a sequence
Содержание Snakky