nama C2 Скачать руководство пользователя страница 5

06

07

WHEN USING JUICER

• MAKE SURE TO PROPERLY READ 

THE INSTRUCTIONS FOR PREPARING 

INGREDIENTS BEFORE INSERTING THEM. 

-  Poorly prepared ingredients may hinder the 

extraction process and/or cause damage to  

the product.

• INGREDIENTS THAT NEED EXTRA CARE 
- When using soft ingredients alone, such as 

oranges, mangoes, bananas, or strawberries, 

the juice or ingredients may collect inside the 

chamber and hopper and not be extracted 

properly. We recommend to add harder type  

of ingredients like carrots, beets, and celery 

on top of or after soft ingredients.

-  When making nut milks, we recommend 

soaking the nuts in water for a minimum of 4 

hours to help soften the nuts for extraction. 

• INGREDIENTS THAT CANNOT BE JUICED 
-  Do not use ingredients such as sesame 

seeds, coffee beans, hard seeds, or pits of 

stone fruits. 

-  Do not use any ingredients that are not 

juiceable in nature, such as lemongrass or 

sugarcane, which may cause damage to  

the product.

-  Do not use frozen ingredients or ice cubes  

for juicing.

• WE RECOMMEND CONSUMING THE JUICE 

IMMEDIATELY FOR OPTIMAL NUTRITION, 

AND CONSUME JUICE WITHIN 3 DAYS 

IF REFRIGERATED IN AIRTIGHT SEALED 

CONTAINER.

• DO NOT USE THIS PRODUCT FOR 

GRINDING GRAINS OR COFFEE BEANS 

(FAILURE TO FOLLOW THIS INSTRUCTION 

MAY CAUSE MALFUNCTION OR DAMAGE 

TO THE PRODUCT.) 

WHEN USING BLENDER

• DO NOT USE IT CONTINUOUSLY FOR 

A DURATION LONGER THAN THE 

STANDARD USAGE TIME. IT MAY 

OVERHEAT THE MOTOR AND CAUSE A 

MALFUNCTION. IF IT HAS TO BE USED 

FOR LONGER THAN THE STANDARD 

USAGE TIME, DO SO WITH A GAP OF 30 

MINUTES OR LONGER. IN MANUAL MODE, 

USE IT FOR 1 MINUTE, 8 TIMES (1 MINUTE 

OF OPERATION FOLLOWED BY 1 MINUTE 

OF STOPPAGE, PROHIBITED TO USE 9 

CONSECUTIVE TIMES) AND, IN AUTO 

MODE, USE IT ONCE FOR 7.5 MINUTES (7.5 

MINUTES OF OPERATION FOLLOWED BY 

30 MINUTES OF STOPPAGE, PROHIBITED 

TO USE 2 CONSECUTIVE TIMES)

• WHEN DETACHING THE JUG FROM THE 

BASE DURING OPERATION, ALWAYS WAIT 

UNTIL BLADES COME TO A COMPLETE 

STOP. When removing food or mixing 

ingredients, make sure to do so after 

separating the jug from the base.

• NEVER OPERATE THE BLENDER WITHOUT 

THE LID IN PLACE.

• WHEN THE POWER IS ON, DO NOT 

REMOVE THE FOOD STUCK ON THE 

WALLS OF THE BLENDER JUG OR MIX 

THE INGREDIENTS. When removing food 

or mixing ingredients, make sure to do so 

after separating the jug from the base. For 

re-operation, stop the device completely 

before use.

• PLEASE BE MINDFUL OF YOUR SAFETY 

WHEN INSERTING YOUR HANDS OR 

KITCHEN TOOLS INTO THE BLENDER JUG. 

ALWAYS STOP OPERATION OF BLENDER 

COMPLETELY AND SEPARATE THE JUG 

FROM THE BASE BEFORE INSERTING 

HANDS OR KITCHEN TOOLS IN THE JUG. 

BLADES ARE SHARP, BE CAREFUL NOT TO 

CUT YOURSELF. 

• DO NOT POUR LIQUIDS OF AN AMOUNT 

GREATER THAN THE MAXIMUM 

ALLOWABLE CAPACITY SPECIFIED ON 

THE RECOMMENDED USAGE DIAGRAM. 

THE AMOUNT OF LIQUID OR FOOD 

INGREDIENTS SHOULD BE MAINTAINED 

-  Do not re-squeeze pulp discharged through  

the pulp outlet.

- Do not operate the product before inserting 

ingredients. 

• DO NOT OVERLOAD INGREDIENTS INTO THE 

HOPPER ABOVE THE MAXIMUM FILL LINE.

-  We recommend not to operate the juicer for 

more than 30 minutes continuously. It may 

cause failure due to overheating of the motor. 

-  Never insert utensils such as a knife or spoon 

into the pulp outlet during the operation. 

Inserting utensils or foreign objects may 

cause damage to the juicer and personal 

injury.

-  Do not push the ingredients in the hopper 

with anything except the pusher provided 

with this juicer. Using anything except the 

pusher provided may stick to the processing 

blade and cause injury and failure.

• DO NOT OPERATE THE CONTROL KNOB 

WITH WET HANDS. IT MAY CAUSE 

ELECTRIC SHOCK, SHORT CIRCUIT OR FIRE.  

• REMEMBER TO OPEN THE JUICE CAP WHEN 

THE CHAMBER BECOMES FULL WHILE 

JUICING AND EMPTY THE PULP CONTAINER 

FREQUENTLY WHEN JUICING IN BULK OR 

MAKING LARGE BATCHES OF JUICE.

-  Juice or pulp may overflow the container.  

The juice can flow backwards into the hopper 

and may leak if the juice cap is closed. 

-  If you do not wash immediately after use, 

it may be caked with pulp, which makes 

it difficult to disassemble and wash or 

may become the cause of performance 

degradation.

• THE CHAMBER SET CANNOT BE 

ASSEMBLED OR DISASSEMBLED WHILE 

ON THE BASE.

OVER THE MINIMUM (100ML) MARK 

AND BELOW THE MAXIMUM (2,000ML) 

MARK. PLEASE USE THE RECOMMENDED 

AMOUNT. If water or food ingredients are 

filled over the maximum limit, they may 

overflow.

• DO NOT TOUCH SHARP BLADES WITH 

BARE HANDS. USE A CLEANING TOOL 

SUCH AS A CLEANING BRUSH TO CLEAN 

THE BLADES AND BOTTOM OF JUG.

• BLADES ARE NOT REMOVABLE FROM 

BLENDER JUG. DO NOT ATTEMPT TO 

SEPARATE THE BLADES FROM THE JUG,  

IT WILL CAUSE DAMAGE TO THE PRODUCT.  

• THE BLENDER BLADES CAN ROTATE 

AT HIGH SPEEDS WHEN IN USE. IF 

THE BLENDER PRODUCES SMOKE OR 

EXCESSIVE HEAT TEMPERATURES, PLEASE 

STOP OPERATION IMMEDIATELY AND 

CONTACT NAMA CUSTOMER SERVICE.

• USE THE PUSHER FOR COLD 

INGREDIENTS ONLY AND, TO PREVENT 

OVERHEATING, DO NOT USE THE 

MANUAL MODE FOR OVER 5 MINUTES 

CONTINUOUSLY. Do not insert hot 

ingredients to cook. For hot ingredients,  

cool them at room temperature before 

placing them in the container.

• WHEN MAKING A SMOOTHIE, IF FROZEN 

INGREDIENTS ARE STUCK TOGETHER IN 

LARGE CHUNKS, ALLOW TO THAW AND 

BREAK UP INTO SMALLER PIECES BEFORE 

PLACING INTO BLENDER JUG.

• PROCESSING EXTREMELY HARD SPICES 

SUCH AS NUTMEG OR HARD SEEDS LIKE 

PITS OF STONE FRUITS MAY DAMAGE  

THE BLADES.

• NEVER BLEND BOILING HOT LIQUIDS. 

ALLOW TEMPERATURE TO DROP BEFORE 

INSERTING INTO BLENDER JUG.

• CAUTION WHEN BLENDING HOT LIQUIDS 

OR INGREDIENTS. DO NOT EXCEED MAX 

LIMIT 1 LITER OR 33.8 OZ. IN JUG.

• DO NOT LEAVE BLENDER UNATTENDED 

WHEN IN USE.

• ONLY USE THE PUSHER PROVIDED WITH 

THIS PRODUCT WHEN BLENDER IS IN USE.

Cautions During Operation

Содержание C2

Страница 1: ......

Страница 2: ...tent and graciously ask for your feedback to help us be better so we can help you create your own wellness journey Cheers to good health Your friends at Nama CHECK US OUT ONLINE AT WWW NAMAWELL COM 02...

Страница 3: ...TOR OFF AND DISASSEMBLE JUICER TO REMOVE THE REMAINING FOOD 13 KEEP HANDS AND UTENSILS OTHER THAN THE TAMPER PROVIDED OUT OF CONTAINER WHILE BLENDING TO REDUCE THE RISK OF SEVERE INJURY TO PERSONS OR...

Страница 4: ...HAT THEY LEARN THE HABIT OF PRACTICING CAUTION ABOUT HOT LIQUIDS TURN OFF THE POWER AND PULL OUT THE POWER PLUG WHEN ASSEMBLING OR DISASSEMBLING PARTS WHEN THE PRODUCT IS NOT USED OR BEFORE CLEANING M...

Страница 5: ...DED USAGE DIAGRAM THE AMOUNT OF LIQUID OR FOOD INGREDIENTS SHOULD BE MAINTAINED Do not re squeeze pulp discharged through the pulp outlet Do not operate the product before inserting ingredients DO NOT...

Страница 6: ...09 NAMA C2 JUICER OPERATION...

Страница 7: ...DETAILS BASE DETAILS Pulp Container Juice Container Sorbet Attachment Cleaning Brush Juice Cap Gasket Juice Outlet Lock Loop Juice Cap Pulp Outlet Release Tab Hopper Lid Maximum Fill Line Hopper Hand...

Страница 8: ...Large Cutout Strainer Top Auger Blade STEP 1 ALIGN VERTICAL GUIDE WITH UNLOCK SYMBOL STEP 2 ROTATE HOPPER TO LOCK Align the vertical Guide mark on the hopper with the Unlock symbol on the chamber Pre...

Страница 9: ...u must lift the chamber set from the base before you can unlock the chamber LOCK UNLOCK OPEN Hopper Handle Control Knob on Base STEP 1 FITTING CHAMBER SET ASSEMBLY ON BASE STEP 2 PLUGGING IN BASE Alig...

Страница 10: ...uicing again If the juicer does not work after these steps turn control knob to center position unplug the juicer then disassemble and clean the chamber set parts before operating the juicer again Cen...

Страница 11: ...Use the pusher to help press ingredients downward As a safety measure the machine will not run if the hopper lid is open Empty the pulp container as needed to prevent it from overflowing Pulp may sti...

Страница 12: ...erry peach or plum have hard seeds or pits Please remove all hard seeds and pits before juicing because they will cause damage to the juicer GINGER CELERY KALE CHARD For fibrous or stringy ingredients...

Страница 13: ...s potassium vitamin C fiber antioxidants and flavonoids FROZEN MANGO Mango sorbet is a nutritious alternative to traditional ice cream Mangoes are high in vitamin C potassium and fiber which minimize...

Страница 14: ...of the plastic juice cap into the silicone stopper and then press around the perimeter HOPPER GASKET Located on the bottom of the hopper this gasket helps to seal the hopper to the chamber To remove h...

Страница 15: ...fter use and store it at a clean place Failure to clean the product right after use can cause its stainless steel components and other parts to corrode or discolor due to salt and pulp of the ingredie...

Страница 16: ...29 NAMA C2 BLENDER OPERATION...

Страница 17: ...Lid Jug Base Power Cord ACCESSORIES JUG PARTS JUG DETAILS BASE DETAILS Control Knob Drive Shaft Pusher Arrow Padding Dosing Cap Lock Lid Clip Maximum Fill Line Jug Handle Blade Assembly Middle Notch s...

Страница 18: ...sing Cap Lid Clip Lid STEP 3 FITTING JUG ASSEMBLY ON BASE STEP 4 BLENDER READY FOR OPERATION Note The blender jug can be installed in two different positions for user preference with the handle in fro...

Страница 19: ...can be paused during operation by pressing the stop button and then resume program by pressing the button again To stop operation turn control knob back to center position Manual Mode Pulse Using the...

Страница 20: ...e the dosing cap on the lid and install the lid onto the jug Install jug onto the base please refer to How to Assemble Blender on page 32 Turn the control knob counterclockwise to select desired auto...

Страница 21: ...ngredients Fruits Vegetables Beans Butternut Squash Carrots Chard Garlic Ginger Kale Lemon Onion Spinach Sweet Potatoes Tomatoes Powders etc Honey Maple Syrup Pepper Red Curry Tofu Liquids Coconut Mil...

Страница 22: ...ender must be assembled correctly on the base Make sure the power is off when assembling or disassembling the product ASSEMBLE IT SO THAT IT IS ALIGNED WITH THE SAFETY SENSOR Check if it is assembled...

Страница 23: ...motor base to rest and cool for about 30 60 minutes before using again BLENDER S GRINDING OPERATION DOES NOT WORK The machine may stop operating if there are too many ingredients or the ingredients ar...

Страница 24: ...d to purchase for any warranty claims This certifies that the Nama C2 Cold Press Juicer Blender model number JB100 is covered under warranty by Nama to be free from defects in material construction an...

Страница 25: ...A Printed with sustainably sourced materials and soy inks Please compost or recycle 2023 2024 NAMAWELL LLC All Rights Reserved NAMA and the NAMA LOGO are registered trademarks of ADC Solutions Health...

Отзывы: