Query the current data compression parameter settings. The response is in the form:
+DS: <direction>,<comp_neg>,<max_dict>,<max_dict>
Test Command: +DS=?
List the supported data compression parameters. The response is in the form:
+DS: (supported<direction>s),(supported<comp_neg>s,(supported
<max_dict>s),(supported<max_dict>s)
Data compression will not work if IRLP is in unacknowledged mode.
Note: The register is not updated right after the user requests new values because the
requested values may or may not be what IRLP will use once a data call is established
due to negotiations with the other peer. If the register is updated right away, this may
give the user the impression that those values will be used during the data call, but
there is no guarantee that will be the case. The real values will only be known once a
data call is established and the negotiation phase is done. For that reason, the values
are written to the register only after a call is established and both sides have
negotiated parameter values. The value of the register will be reset to default value
(3) after the call is completed.
B.32 +DR
–
D
ATA
C
OMPRESSION
R
EPORT
L
EVEL
Set Command: +DR=[<mode>]
Set the data compression reporting level.
<mode> can take on the following values:
0
Disable data compression reporting (default)
1
Enable data compression reporting
If reporting is enabled, the following intermediate result codes are transmitted by the
A3LA-R:
+DR: NONE No data compression
+DR: V42B Data compression in use in both directions
+DR: V42B RD Data compression in use in receive direction only
+DR: V42B TD Data compression in use in transmit direction only