The A3LA-R allows users to configure its data port communication parameters. The three
configuration types are active, factory default, and stored.
The active configuration is the set of parameters currently in use. They can be changed
by individually via specific AT commands.
The factory-default configuration is stored in permanent memory. Recall this
configuration at any time with the AT&Fn command.
Two groups of settings, or “profiles,” can be stored as user-defined configurations.
o
First create desired active configurations and then write them to memory using the
AT&Wn command.
o
These profiles can be designated to be loaded as the active configuration upon
A3LA-R power-up with the AT&Yn command.
o
The A3LA-R can be reset without loss of power to these profiles with the ATZn
command.
o
The configuration settings are stored in “S-register” locations and are detailed in