24
Procedure)1. Push the Start Switch
2. is displayed. This indicates that the Maximum Motor Speed is not set.
3. Push the Start Switch.
4. is displayed. This indicates that the Maximum Motor Speed is ready to be
set. Maximum motor speed is displayed on the Digital Speed Indicator.
5. The Digital Speed Indicator will oscillate between on the selected motor speed and motor
speed can be selected by turning the potentiometer. The speed control range is 5,000-
30,000min
-1
.
6. Push the Reset Switch to send the settings to memory Parameter number will be
displayed depending on the position of the potentiometer.
7. If you desire to set other parameters turn the potentiometer to select the parameter to be set.
8. If you are finished setting parameters, turn the Power Switch off.
▲Setting External Motor Start Signal Control Mode
・During Auto Control Mode the motor Start signal can either by a direction signal and a Start signal
or a FWD. Start and a REV. Start signal. When is set to the rotation direc-
tion is controlled by Pin No.2 DIR̲IN, FWD. (Open), REV.(Closed) and the Start signal is control-
led by Pin No.14 : START When is set to FWD. rotation is controlled by Pin
No.14 : START and REV. rotation is controlled by Pin No.2 : DIR̲IN.
Procedure)1. Push the Start Switch
2. is displayed. This indicates that the control mode is set to derection signal
and start signal.
3. Push the Start Switch
4. is displayed. This indicates that the control mode is set to FWD. ON, REV.
ON mode.
5. Push the Error Reset Switch to send the settings to memory will be displayed
depending on the parameter being set.
6. If you desire to set other parameters push the Motor Speed Adjustment Switch to select
the parameter to be set.