6. SYSTEM OPERATING INSTRUCTIONS

Your new system is now ready to be used.  Here are a few simple guidelines to follow when you are 
using your Nadair  Central Vacuum System:  Insert the wall  end of the hose into one of the  vacuum 
valves installed throughout your home, and you are ready to start, press the switch on the hose handle!

NOTE

In regards to the low voltage system:  All vacuum inlet valves are fitted with two (2) springloaded metal 
pins (see inside the valve opening). When the two (2) metal parts of the hose wall end are in contact 
with the two (2) pins inside the valve, the system is energized. You may now turn it on or off from the 
hose handle switch (if this option was selected).
The low voltage cable is connected in parrallel from every valve, it runs all along the pipe network and 
brings the power to the the remote switch so to remotely start or stop the power unit in all safety.
A standard flexible hose, not fitted with an interruptor, will start the power unit as soon as it is inserted in 
the valve opening.

7. SYSTEM  MAINTENANCE

FILTRATION SYSTEM

In  order  to  maintain  optimal  air 
quality in your home, the power unit 
comes supplied with a high efficiency 
HYBRID filtering system.

permanent 

polypropylene 

washable and reusable filter together 
with  an  optionnal 

22,5L

disposable 

filter bag.
The permanent filter must be in place 
at  all  times,  the  filter  securing  strap 
must be tightened just so as to insure 
no  fly-by  of  debris  into  the  motor 
housing.

IMPORTANT

This  Nadair  hybrid  power  unit  may 
be  used  with  or  without  a 

22,5L

 

disposable bag.
3 bags pak #: 

FD-22.5L-3NAD

The  disposable  bag  installs  as 
shown here :
1-Remove the debris canister.
2-Remove the dirt filled bag.
3-Install the new bag by twisting it.
4- Verify and clean (if necessary)

the permanent filter.

5- Replace the debris canister and

secure the latches.

NOTE

When replacing the  disposable  bag, make  sure  that  the rubber  diaphragm  is  correctly  installed  onto the 
intake PVC pipe. Make sure that the bag is not cut or damaged. Make sure that the canister is secured in 
place prior to restarting the power unit.  

It is recommended to replace the disposable bag or to empty 

the debris canister as well as to clean the permanent filter 3 or 4 times per year.

 If the system is used 

more frequently than normal, repeat the above procedure more often.

IMPORTANT

NEVER USE this system to pick up liquids, mud or combustible materials. To vacuum baking flower, talcum 
powder, cement or gypsum dust, will have for effect to obstruct and eventually clog the filter media; you have 
to clean the filter several time during and after such pick-ups. Otherwise the power unit performances will 
be affected, the motor will overheat and may be damaged.

MOTOR

This Nadair power unit  is equipped with a soft-start controler and a delayed stop.  A warning is automatically 
programmed after 500 hours of usage.  The inspection and the maintenance of this appliance must be done 
in  an authorized  service center. A Mini-breaker shall cutt-off power to protect the motor in the event of a 
power surge which may cause the motor to overheat. The low voltage technology system communicates the 
power unit status through a muticolor LED on the side of the unit.  Please consult the interpretation chart in 
section 8.

Содержание 600-AL-32

Страница 1: ...User Manual Central Vacuum System Model Number NADAIR 600 AL 32 www NadairVac com ...

Страница 2: ... to be respected at all times 3 Models 5 4 Installation 5 Power Unit 5 Low voltage system 5 Installation instructions 6 System operation instruction 6 7 System maintenance 6 Filtration system Motor 8 Troubleshooting 7 General 9 Low voltage system 8 LED Interpretation chart 10 Safety notes 8 11 Nadair s warranty 9 Page 2 ...

Страница 3: ...ve remained in the pipe If any remove the obstructing objects to ensure maximum airflow Keep the power cord from any contact with any warm objects or surfaces Do not unplug the power cord by pulling on it always remove directly at the electrical oulet Do not use the system or its accessories with wet hands Keep hair clothing fingers any other body parts or other objects out of or away from any ope...

Страница 4: ...installation of the system or the power unit made without respecting the directives of this document will equally be considered as misuse All conditions and restrictions are set forth in the limited warranty and in the user manual To optimize the performances and the life of your Nadair power unit it is important to do regular maintenance and cleaning of the filter according to the guidelines list...

Страница 5: ...inimizethetransmis sion of vibrations into the building 2 Installation on a gypsum wall Gyprock Prepare the wall by installing a plywood mounting board not provided of 16 40cm high and 0 75 2cm thick wide enough to be screwed to at least 2 studs Drill three 3 3 8 10mm holes with a wood drill bit Insert the supplied rubber inserts Fasten the steel mounting bracket with the supplied screws 3 Install...

Страница 6: ...h or without a 22 5L disposable bag 3 bags pak FD 22 5L 3NAD The disposable bag installs as shown here 1 Remove the debris canister 2 Remove the dirt filled bag 3 Install the new bag by twisting it 4 Verify and clean if necessary the permanent filter 5 Replace the debris canister and secure the latches NOTE When replacing the disposable bag make sure that the rubber diaphragm is correctly installe...

Страница 7: ...ot work after the above diagnostic bring the unit to the nearest authorized service center SITUATION VERIFICATION LOW OR NO SUCTION OR AIR FLOW AT ALL Verify the cleaning tool or the hose for possible obstruction If the hose is obstructed try to massage the clog out Try to reverse the hose by inserting the cleaning end of the hose in the wall valve and making contact with the two 2 small metal con...

Страница 8: ... Hammer Phillips head screwdriver cruciform Measuring tape Level Drill with wood or concrete bit of 3 8 10mm Pliers Wire stripper Status Color Legend OFF The power cord is unplugged No power GREEN The power cord has just been plugged in or the power has been restored The LED will flash rapidly for a few seconds and will then become solid again GREEN The power unit is operational AMBER Stop the pow...

Отзывы: