background image

1. Important instructions related to safety

CAREFULLY READ ALL OF THESE INSTRUCTIONS

PRIOR TO USE THIS CENTRAL VACUUM SYSTEM

When using an electrical appliance, it is necessary to obey certain basic precautions

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

- Unplug the power cord from electrical outlet before making any power unit maintenance.
- Do not install outdoors, protect against weathering and do not use on wet surfaces.
- This appliance must not be used as if it is a toy. It is therefore necessary to be very prudent when the system is used

by children or when in use in the proximity of a child or infant.

- This system must be used in conformity with the instructions provided in this manual.  Only use the accessories

recommended by the manufacturer.

- Do not use the system if the power cord or if the electrical outlet are damaged, if the system does not function

normally, if it was dropped, was left outdoors in bad weather for an extended period of time or if it was 

immersed

in liquid, the power unit must be sent to an authorized service center.

- Do not use the power cord to pull or lift the power unit, nor use it like a handle.  Be careful not to pinch it in a door, do

not let it hang on a sharp corner or edge.

- Examine the openings for foreign objects which may have remained in the pipe.  If any, remove the obstructing

objects to ensure maximum airflow.

- Keep the power cord from any contact with any warm objects or surfaces.
- Do not unplug the power cord by pulling on it, always remove directly at the electrical oulet.
- Do not use the system or its accessories with wet hands.
- Keep hair, clothing, fingers, any other body parts or other objects out of or away from any openings or moving parts

of the system.

- All functions of the system must be deactivated prior to removing the power cord from the electrical socket.
- Take the necessary precautions when using the system in a stairs.
- Do not use the system to pick up flamable liquids or fuels (i.e. gasoline), nor use the system in areas where such

liquids may be present.

- Only plug in the power cord into properly grounded electrical socket. For more information on this subject, please see

‘’Grounding specifications’’ in section 2.

- The exhaust of the power unit must not give right against a wall, a ceiling or be inside a closed space inside a building

or structure.  It is recommended that the exhaust be vented outdoors.

- Do not pick up hot ashes, red ambers, smoking hot material, incandescent material, cigarette butts, matches etc...
- Do not put anything on top of the power unit or near it, because this could cause the unit to overheat
- DO NOT use the power unit if the pipe network is clogged, this will cause the unit to overheat.

KEEP THESE INSTRUCTIONS IN A SAFE PLACE

THIS  POWER UNIT IS FOR DOMESTIC USE ONLY

Page 3

Содержание 600-AL-32

Страница 1: ...User Manual Central Vacuum System Model Number NADAIR 600 AL 32 www NadairVac com ...

Страница 2: ... to be respected at all times 3 Models 5 4 Installation 5 Power Unit 5 Low voltage system 5 Installation instructions 6 System operation instruction 6 7 System maintenance 6 Filtration system Motor 8 Troubleshooting 7 General 9 Low voltage system 8 LED Interpretation chart 10 Safety notes 8 11 Nadair s warranty 9 Page 2 ...

Страница 3: ...ve remained in the pipe If any remove the obstructing objects to ensure maximum airflow Keep the power cord from any contact with any warm objects or surfaces Do not unplug the power cord by pulling on it always remove directly at the electrical oulet Do not use the system or its accessories with wet hands Keep hair clothing fingers any other body parts or other objects out of or away from any ope...

Страница 4: ...installation of the system or the power unit made without respecting the directives of this document will equally be considered as misuse All conditions and restrictions are set forth in the limited warranty and in the user manual To optimize the performances and the life of your Nadair power unit it is important to do regular maintenance and cleaning of the filter according to the guidelines list...

Страница 5: ...inimizethetransmis sion of vibrations into the building 2 Installation on a gypsum wall Gyprock Prepare the wall by installing a plywood mounting board not provided of 16 40cm high and 0 75 2cm thick wide enough to be screwed to at least 2 studs Drill three 3 3 8 10mm holes with a wood drill bit Insert the supplied rubber inserts Fasten the steel mounting bracket with the supplied screws 3 Install...

Страница 6: ...h or without a 22 5L disposable bag 3 bags pak FD 22 5L 3NAD The disposable bag installs as shown here 1 Remove the debris canister 2 Remove the dirt filled bag 3 Install the new bag by twisting it 4 Verify and clean if necessary the permanent filter 5 Replace the debris canister and secure the latches NOTE When replacing the disposable bag make sure that the rubber diaphragm is correctly installe...

Страница 7: ...ot work after the above diagnostic bring the unit to the nearest authorized service center SITUATION VERIFICATION LOW OR NO SUCTION OR AIR FLOW AT ALL Verify the cleaning tool or the hose for possible obstruction If the hose is obstructed try to massage the clog out Try to reverse the hose by inserting the cleaning end of the hose in the wall valve and making contact with the two 2 small metal con...

Страница 8: ... Hammer Phillips head screwdriver cruciform Measuring tape Level Drill with wood or concrete bit of 3 8 10mm Pliers Wire stripper Status Color Legend OFF The power cord is unplugged No power GREEN The power cord has just been plugged in or the power has been restored The LED will flash rapidly for a few seconds and will then become solid again GREEN The power unit is operational AMBER Stop the pow...

Отзывы: