WARNING

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. THE
LIGHTNING FLASH WITH ARROWHEAD SYMBOL, WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO
ALERT THE USER TO THE PRESENCE OF UNINSULATED “DANGEROUS VOLTAGE” WITHIN THE PRODUCT’S
ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO
PERSONS. 
THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE IS INTENDED TO ALERT THE USER TO THE
PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS IN THE
LITERATURE ACCOMPANYING THE APPLIANCE

CAUTION

Changes or modifications to this equipment not expressly approved by NAD Electronics for compliance could void the
user’s authority to operate this equipment.

CAUTION REGARDING PLACEMENT

To maintain proper ventilation, be sure to leave a space around the unit (from the largest outer dimensions including
projections) equal to, or greater than, shown below.
Left and Right Panels : 10 cm
Rear Panel : 10 cm
Top Panel : 50 cm

IMPORTANT INFORMATION FOR UK CUSTOMERS

DO NOT

cut off the mains plug from this equipment. If the plug fitted is not suitable for the power points in your

home or the cable is too short to reach a power point, then obtain an appropriate safety approved extension lead or
consult your dealer. If, nonetheless, the mains plug is cut off, REMOVE THE FUSE and dispose of the PLUG immediately,
to avoid possible shock hazard by inadvertent connection to the mains supply. If this product is not provided with a
mains plug, or one has to be fitted, then follow the instructions given below:

IMPORTANT

DO NOT

make any connection to the larger terminal which is marked with the letter ‘E’ or by the safety

earth symbol or coloured GREEN or GREEN AND YELLOW.
The wires in the mains lead on this product are coloured in accordance with the following code:

BLUE - NEUTRAL
BROWN - LIVE

As these colours may not correspond with the coloured markings identifying the terminals in your plug, proceed as
follows:

The BLUE wire must be connected to the terminal marked with the letter ‘N’ or coloured BLACK.
The BROWN wire must be connected to the terminal marked with the letter ‘L’ or coloured RED

When replacing the fuse, only a correctly rated and approved type should be used, and be sure
to re-fit the fuse cover.

IF IN DOUBT CONSULT A COMPETENT ELECTRICIAN

This product is manufactured to comply with the radio interference requirements of EEC DIRECTIVE 89/68/EEC and
73/23/EEC

NOTES ON ENVIRONMENTAL PROTECTION

At the end of its useful life, this product must not be disposed of with regular household waste but must be returned
to a collection point for the recycling of electrical and electronic equipment. The symbol on the product, user's manual
and packaging, point this out.
The materials can be reused in accordance with their markings. Through re-use, recycling of raw materials, or other
forms of recycling of old products, you are making an important contribution to the protection of our environment. 
Your local administrative office can advise you of the responsible waste disposal point.

RECORD YOUR MODEL NUMBER (NOW, WHILE YOU CAN SEE IT)

The model and serial number of your new Integrated Amplifier located on the back of the cabinet. For
your future convenience, we suggest that you record these numbers here:

SAFETY INFORMATION

Introduction

ENGLISH

FRANÇAIS

DEUTSCH

NEDERLANDS

ESP

AÑOL

IT
ALIANO

POR

TUGUÊS

SVENSKA

Model No. :________________________

Serial No. :______________________

 

 

M3 10262005.qxd  1/3/2006  2:49 PM  Page 4

Содержание M3 - 2

Страница 1: ...DS ESPA OL ITALIANO PORTUGU S SVENSKA Owner s Manual Manuel d Installation Bedienungsanleitung Gebruikershandleiding Manual del Usuario Manuale delle Istruzioni Manual do Propriet rio Bruksanvisning M...

Страница 2: ...mounting of the product should follow the manufacturer s instructions and should use a mounting accessory recommended by the manufacturer 9 A product and cart combination should be moved with care Qui...

Страница 3: ...e product due to lightning and power line surges 16 Power Lines An outside antenna system should not be located in the vicinity of overhead power lines or other electric light or power circuits or whe...

Страница 4: ...minal which is marked with the letter E or by the safety earth symbol or coloured GREEN or GREEN AND YELLOW The wires in the mains lead on this product are coloured in accordance with the following co...

Страница 5: ...suite of convenience features Speaker switching for two pairs of speakers and very flexible tone controls are provided as is a Zone 2 output with its own independent set of commands and dedicated ZR3...

Страница 6: ...e display and digital functions operate from an independent power supply to prevent any interference with the analog signal path POWER AMP HIGHLIGHTS The M3 features a Dual Mono design with separate u...

Страница 7: ...utton on the rear panel to turn the M3 to standby 4 Press power button on the front panel to turn on the M3 5 Press and toggle the listen button to select the source A NOTE ON INSTALLATION Install thi...

Страница 8: ...10 12 11 13 15 16 14 RS 232 Spade Wire Pin 8 ENGLISH FRAN AIS DEUTSCH NEDERLANDS ESPA OL ITALIANO PORTUGU S SVENSKA FRONT PANEL CONTROLS FIGURE 1 Identification of controls REAR PANEL CONNECTIONS AND...

Страница 9: ...VENSKA 1 1 2 2 3 4 6 5 7 12 9 10 12 12 8 4 ZR3 REMOTE CONTROL FIGURE 5 1 4 1 2 3 RELEASE CR2025 OPEN CR2025 11 A A R 6 A A R 6 A A R 6 PRESS IN AND LIFT TAB TO REMOVE BATTERY COVER OUT FROM RECESS PLA...

Страница 10: ...UT 6 BALANCED and then return to DISC Release the listen button to stop the sequence Assigning User Names input selection Renaming inputs is advantageous when using auxiliary equipment not representin...

Страница 11: ...ilt frequency response diagrams 9 biamp crossover frequency selection If one uses smaller shelf type speakers in conjunction with a powered subwoofer refer to PRE OUT 2 section under Rear Panel Connec...

Страница 12: ...PRE OUT 2 This secondary preamplifier output follows the volume level of the PRE OUT 1 Adjust the biamp high pass frequency settings for PRE OUT 2 using the biamp Crossover Frequency Selection to matc...

Страница 13: ...ers to your M3 The high current binding post terminals can be used as a screw terminal for cables terminating in spade or pin connectors or for cables with bare wire ends SPADE CONNECTORS Figure 3 The...

Страница 14: ...DB 9 female RS 232 serial cable between your Windows PC and the M3 Do not use a null modem type of RS 232 cable Some Windows PC s may not have RS 232 serial connectors In this event use a standard of...

Страница 15: ...to enable either speaker A B or both A B 5 MODE Press the MODE button to toggle through the four listening modes A press longer than one second will advance the mode selection to the next state as fo...

Страница 16: ...navigation buttons will be inoperative The TITLE button will become a Repeat function button the MENU button will become a Random function button and the DISP button will become a Time function button...

Страница 17: ...connections to all speakers in the system Set biamp to FULL RANGE Select Stereo Mode REMOTE CONTROL HANDSET NOT WORKING Batteries flat or incorrectly inserted IR transmitter or receiver windows obstru...

Страница 18: ...IHF dynamic power at 2 785W 29 0dBW Damping factor ref 8 50Hz 150 Input impedance 20k 680pF Input Sensitivity for rated power into 8 1 38V Voltage gain 29dB Frequency response 20Hz 20kHz 0 03dB Frequ...

Страница 19: ..._ _ _ _ _ _ _ _ _ _ _ _ _ CD CD _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ TUNER TUNER _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ INPUT 4 INPUT 4 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ INPUT 5 INPUT 5 _ _...

Страница 20: ...RNATIONAL A DIVISION OF LENBROOK INDUSTRIES LIMITED All rights reserved No part of this publication may be reproduced stored or transmitted in any form without the written permission of NAD Electronic...

Отзывы: