Magnum IV Control Manual for Gyro Tech Swing Door Systems
Page 22
www.NabcoEntrances.com
1/4/06
b.
Cut the connectors from the Brown and Black wires on the GT 300/400/500 Magnum
Micro
Switch
Harness
P/N
21-9934
as
shown below. Connect the Brown and Black wires
to
Continuous
Safety”
input
of
Terminal
Block.
(
Between Terminal Block #3 violet and
#
5 red) as shown below.
c.
Also cut the connectors off the Panic Latch harness and connect these wires to
“Continuous Safety” input of Terminal Block.(Between Terminal Block #3 violet and
F
IGURE
17 - P
ANIC
L
ATCH
AND
P
ANIC
B
REAKOUT
L
IMIT
S
WITCH
W
IRING
I
NSTRUCTIONS
F
IGURE
16 - M
ICRO
S
WITCH
H
ARNESS
Black
Black
Brown
Brown
DN0061
USE THESE CONNECTIONS ON INSWING
DOORS WITH PANIC BREAKOUT
DN0049
Panic Latch must be flipped.
Arrow marked "EXT" must
point into the building.
(Contacts must close when
door is broken out)
Back Check Limit Switch
Harness Assy
(Black and Brown)
Breakout Limit Switch: N.O.
Terminal Block # 3 & # 5
MUST be connected to Continuous Safety input,
Breakout Limit Switch Signal and Panic Latch Signal
When the unit has Panic Breakout feature,
Panic Latch Kit
Part # 11- 0941
Red
Red
Brown
Black
Red: Comm, Blue: N.C.
for Magnum Board
300/400/500 Harness
Part # 21-9934
2
3
4
F
F
O
Selector Switches
ON
OFF
1
BR
OWN
BL
AC
K
RE
D
WHITE
VIOLE
T
ORANGE
Motor
J5
Pwr
Aux
J4
R40
R29
R27
R24
R21
R13
R8
CLOSE
LCHK
TDPG
TDAS
BCHK
OPEN
STOP
J2
J3
Relay
LIMIT
CURRENT
R23
Relay
Transformer
Magnum IV control
Operator Assembly