![Nabco GYRO TECH Magnum IV Control Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/nabco/gyro-tech-magnum-iv-control/gyro-tech-magnum-iv-control_wiring-and-adjustment-manual_3083835014.webp)
Magnum IV Control Manual for Gyro Tech Swing Door Systems
Page 14
www.NabcoEntrances.com
1/4/06
This section details the installation and adjustments of the Magnum IV control in a GT-300, GT-400 and GT-500 swing
door unit.
Step 1: Install all components as per the applicable hardware installation manual.
Step 2: Connect all wiring and harnesses as per the following wiring information as it pertains to wiring and adjustments
for GT-300, GT-400 and GT-500 Operators.
Back Check and Latch Micro Switches:
The
operators
used
with the GT-300, GT-400 and GT-500’s provide the necessary latch check and back
check limit switches the Magnum IV control requires for correct operation. These switches are mounted
on the top of the operator assembly as illustrated in the diagram below. Note position of cams on right
hand
versus
left
hand
operator.
Section A
Wiring and Adjustment for GT-300,
GT-400 and GT-500 Operators
F
IGURE
6 - L
IMIT
SWITCH
CONFIGURATION
B lack
B ro wn
R ed
B lu e
Green
W hit e
Latch-check
Limi t switch
Breakout
Limit switch
Back-check
Limit switch
Lef t H an d Operator shown
In D OOR C LOSED posit ion
R ight H and Op erato r sho wn
In D OOR C LOSED p osit ion
B lack
B rown
W hit e
R ed
Green
B lu e
Back-check
Limit swi tch
Breakout
Limit swi tch
Latch-check
Limi t switch
D N 0051