31 of 31
www.NabcoEntrances.com
GT1175 Slide Door Opus Control Wiring and Programming Manual
Rev. 8-11-21
P/N C-00391
Error Messages
Opus Error Msg
NET-HT Error Msg
Resolution
No Motor
Motor disconnection error
►
Check all connections between the Control and Motor.
Thrml Warning
Thermal-on warning
►
Check all connections between the Control and Motor.
►
Cool down the motor, and adjust the recycle sensitivity and Open/
Close speed.
No Load
No load error
►
Check operator (gear cracked, belt skipped).
Electrical Lock
Electrical lock error
►
Check lock settings and wiring.
►
Ensure lock delay is long enough, and not set to (After Lock Input).
►
Ensure no programmable inputs are set to “Unlock Input” assuming
there is no lock feedback.
61 Sensor
T3:61 sensor error
►
Check Sensor wiring.
►
Check Settings on Sensor and/or Control related to
Sensor Monitoring.
►
Try a new Sensor.
62 Sensor
T4:62 sensor error
6B Sensor
T5:6B sensor error
SWL Sensor
T6:SWL sensor error