Omega Dimmer series User manual version 1.0             09.2011 

17 

5. Appendix

 

 

DMX-512 Protocol 
 

DMX-512 protocol has 512 channels 

in 

one 

universs. Channels 

(adress) can 

be 

committed in  any way  depending  on the device. To  operate  equipment  with DMX-512  protocol is 
necessary one  channel or multiple channels in  a  row  depending  on  type  of  device. User sets  up  the 
address  of  the  equipment, which coincides with the  light control panel installed. There  are a  lot of 
equipment, which can 

be 

controlled via DMX-512 protocol, and they may have different 

DMX channel number, so the  start address must  be  selected in advance. DMX channels  should 
never overlap with  each  other. If  the DMX channels are overlapping, equipment can run  wrongly. If 
you use 

the same type 

of equipment can impose a 

range 

of 

facilities with 

the 

same starting address, only take into 

account that 

the 

installation will 

work 

exactly 

the 

same and you will not be able to drive one of these machines separately.

 

 
 

Important:

 
EIA-485  standard  requires  that  the  device  can  be  connected  to  one  DMX  univers  with  a 

series circuit. In accordance with the provisions of the standard in one DMX series circuit can connect 
only 32 devices. To be able to connect more than 32 devices in one DMX univers, you need to use the 
DMX  signal  splitter  vith  the  recovery  function,  which  inputs  and  outputs  are  optically  isolated. 
Otherwise, the DMX-512 signal may be distorted and device management from the light control panel 
will not be possible. 

 

DMX Ddata cable

 

 

Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 
applications. Standard microphone cables cannot transmit DMX data reliably over long 
distances. The cable will have the following characteristics: 
 

2-conductor twisted pair plus a shield 
Maximum capacitance between conductors 

– 30 pF/ft. 

Maximum capacitance between conductor and shield 

– 55 pF/ft. 

Maximum resistance of 20 ohms / 1000 ft. 
Nominal impedance 100 

– 140 ohms

 

 

 

CABLE CONNECTORS 

 

Cabling must have a male XLR connector on one end and a female XLR connector on the other 
end.

 

 

DMX connector configuration

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание OMEGA +

Страница 1: ......

Страница 2: ...requirements 8 Cooling 8 OMEGA dimmer package 8 Check transportation damage 8 Package content 8 Instalation 8 Preperation of the necessary components 8 Assembly of main cable 8 Starting the system 9...

Страница 3: ...rials In the event that a fixture must be returned to the factory it is important that the fixture be returnedin the original factory box and packing Power Before powering on the unit is to make sure...

Страница 4: ...the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please cont...

Страница 5: ...of the graphic display independently of the DMX input The Test mode allows for two output signal set sizes single channel C or group G Operating the dimmer in Chase mode replays a prerecorded sequenc...

Страница 6: ...Omega Dimmer series User manual version 1 0 09 2011 6 OMEGA rackmount 12 channel dimmer owerveiw OMEGA and OMEGA rackmount back panel owerveiw...

Страница 7: ...Omega Dimmer series User manual version 1 0 09 2011 7 OMEGA W wallmount 24 channel dimmer owerveiw...

Страница 8: ...n guide Appendix department with other useful information Before the installation of the system read the first two chapters Specification of system OMEGA dimmers Setup Dimmer OMEGA is designed for ins...

Страница 9: ...on the right side of corps Instalation Preperation of the necessary components Dimmer OMEGA is shipped with out a cable that is secured in place In order to properly carry out the installation of a d...

Страница 10: ...erly connected and isolated and complies with both ends of the connection Make sure all ground wires are connected properly Using a multimeter check short circuit between phases neutral and earth Turn...

Страница 11: ...enu and service functions Referred to as button names are given in square brackets but the lettering on the display in quotation marks Base screen mode In the dysplay you can see DMX adress and value...

Страница 12: ...rature sensor short circuit Fan speed 100 T1 25 T2 nc C Software version date Prog vers 5 00 Date feb 29 2008 DMX Parameters DMX adress Max adress count FPS frames per second Err count oferrors in las...

Страница 13: ...er In Test mode channel output levels stays only at test mode if you exit from Test mode output levels are dropped down Chase pre recorded step chase playback and editing Contains the following functi...

Страница 14: ...ufacturers default settings More technical setup menu Requires PIN1 code pin1 code 1234 Technical setup menu Preheat Preheat setup for idividual channel using graphical editor Limit from 0 15 Preheat...

Страница 15: ...ent lamp management curves but the last Non dim for Relay mode Square Linear default Lin Law NACurve S Curve Non dim for Relay mode Engineer menu engineering settings PIN2 required Engineering menu de...

Страница 16: ...BBBBCCCC ABCABCABCABC default AAAAAAAAAAAA DMX unplug DMX input signal is lost setup Allows you to select the state which occurs when DMX signal is lost Blackout all outputs 0 Signal Hold Last remains...

Страница 17: ...machines separately Important EIA 485 standard requires that the device can be connected to one DMX univers with a series circuit In accordance with the provisions of the standard in one DMX series c...

Страница 18: ...Pin 3 Pin 3 Do not use Do not use Do not use Do not use Maintenance To maintain optimum performance of equipment and reduce wear and tear it is advisable to clean them regularly Frequency of usage an...

Страница 19: ...ves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA please include th...

Страница 20: ...0 A Surage Protection lamps turned off at 285V Full Voltage Range 180 380 V THERMAL Maximum ambient temperature 40 C Minimum ambient temperature 20 C Operating Humidty 10 85 Cooling air cooled fan CON...

Страница 21: ...85V Full Voltage Range 180 380 V THERMAL Maximum ambient temperature 40 C Minimum ambient temperature 20 C Operating Humidty 10 85 Cooling air cooled fan CONTROL PROGRAMMING Control DMX 512 Test or Ch...

Страница 22: ...0 A Surage Protection lamps turned off at 285V Full Voltage Range 180 380 V THERMAL Maximum ambient temperature 40 C Minimum ambient temperature 20 C Operating Humidty 10 85 Cooling air cooled fan CON...

Отзывы: