Omega Dimmer series User manual version 1.0 09.2011
16
"= 3 min "
-default.
"Phase sequence"
- Output Channels connected to phase setup. Specifies in what order the
phases are connected to the channels:
Example:
AAAABBBBCCCC;
ABCABCABCABC -
default
;
AAAAAAAAAAAA.
"DMX unplug"
-
DMX input signal is lost setup. Allows you to select the state, which occurs when
DMX signal is lost:
"Blackout"
-
all outputs = 0;
"Signal Hold Last"
-
remains last incoming DMX signal values, until the signal is not
renewed (default).
"Potentiometers"
- Output channels analogue
potentiometer settings.
"Voltage history"
-
Deleting history of overvoltage. Request code PIN3 (****).