28
FIGURE - 5.2
Ring Volume
Tuning
Brigthness Tuning
Colour/Cantrast
Tuning
Door Open Button
Stairs Automation
Panel Display
CCTV Display
Security
Doorkeeper
Handset
Screen
FIGURE - 5.1
DC24V
±
1 (from central unit)
0.4W (Min.), 14W (Max)
8 Wires
Full duplex
3 doorbell melodies , 2 phone melodies, 1 Alarm melody
ABS
4” S/B CRT - 4.3” Color LCD
Calling time : 30 sec, Talking Time : 60 sec
220 (Heigth) x 200 (Width) x 55 (depth) mm
Audio - Brigthness - Colour / Contrast
-20°C - +40°C
IP20
TECHNICAL CHARACTERISTICS
Operation voltage
Power consumption
Connection
Audio communication
Calling Melody
Material Content
Monitor
Monitor operating time
Dimensions
Settings
Operating temperature
Protection class
Functions
MONITOR FUNCTIONS
ON OFF
12V
GND
Vid
24V
GND
V1
V2
A1
A2
D1
D2
BELL
GND
F
A
B
D
C
E
FIGURE - 5.3
A- System connection terminal
B- Doorbel connection terminal
C- 1st ID switch ( master ID )
D- 2nd ID switch (slave ID )
E- External Video Input.
F- 75ohm Video Terminating switch
ID settings:
Diagram-5.3.C shows the main ID group and diagram-5.3.D shows the slave monitor ID group. Second ID alwasy set to “1” if only one monitor used in
one flat.
Example: ID settings for 3 flats;
1st Monitor :
1. ID = 1, 2. ID = 1
2nd Monitor :
1. ID = 2, 2. ID = 1
3rd Monitor :
1. ID = 3, 2. ID = 1
Example: ID settings for 3 flats with 1 slave monitor for last monitor:
1st Monitor :
1. ID = 1, 2. ID = 1
2nd Monitor :
1. ID = 2, 2. ID = 1
3rd Monitor / master :
1. ID = 3, 2. ID = 1
3rd Monitor slave :
1. ID = 3, 2. ID = 2
Be careful to make sure all IDs are set regarding to table-5.1 and 5.2 before the system is energised. Be careful that all IDs are set
unique and diffrent from “0”.
Screen:
Monitor, black/white CRT or colourful LCD
Handset:
Allows audio output and input with speaker and microphone
Door Open Button
:
It is used to open entrance door.
Stairs Automation :
It is used to ligth up stairs.
Panel Display :
When it is pressed to panel display button, monitor gives the view of camera
on the panel for 30 seconds. If there is more than one panel on the system, if it is pressed to
button again during monitor have view of first panel, the monitor gives the view of second panel
if there is not another panel, display turns off.
CCTV Display :
If there is a CCTV camera on the system, it gives the view of CCTV camera
on the monitor for 30 seconds. If there is two CCTV camera on the system, before time is over
when it is pressed again displays the other CCTV camera’s view. If not, display turns off.
Security :
It is used to call security. When the handset is hooked and button is pressed, security
phone is called. When the security accept the call, communication starts. If either side does not
end the phone call, after 60seconds system automatically ends the call. If there is more than
one security on the system, in order to call first security press button, to call second security
press the switch of the handset once and press button. If the same process is repeated, other
securities are called.
Doorkeeper :
It is used to call doorkeeper in NVM series. When the handset is hooked then
button is pressed, doorkeeper phone is called. If there is more than one doorkeeper in the
system, in order to call first doorkeeper press the button, to call second doorkeeper press the
button again and then other securities will be called
Ring volume tuning:
Allows you to adjust ring volume tone.
Colour / Contrast tuning:
Allows you to adjust colour for LCD monitors and contrast for black
/ white CRT monitors.
Brightness tuning:
Allows you to adjust brightness.
External video Input:
Additional camera connection shown in figure 5-3-D. Indoor Camera
can be monitored by when somebody press door bell button or can be monitored by CCTV
button as shown in figure 5.1 . In case of using external video input , 2nd group DIP switch must
be set by 4th digit UP position (”1”) as shown in figure 5.3. Otherwise, if there is no external
video input this switch must be DOWN position (”0”). Please refer table-5.3 for 2nd group of
DIP switches for external video input.
75ohm video termination switch:
This switch must be ON position as shown in figure-5.3.F.
Note:
If system is installed with an alarm dedector, all the monitors will emerge householders
by alarm event for 1 minute.
Call with the panel
Call with the security/ doorkeeper
Door Automation Control
Stairs Automation Control
CCTV Display
Panel Display
NVM-500MB/MC - ND-107K-7 - ND-108K-7 MONITOR
Содержание GK-04-8
Страница 2: ......
Страница 50: ...45 FARKLI BA LANTI UYGULAMALARI BÖLÜM 10 ...
Страница 68: ......
Страница 116: ...45 DIFFERENT WIRING COMBINATIONS SECTION 10 ...
Страница 132: ...KK VBUS 7 8_140212_ENG_00 www na de com tr info na de com tr 0800 261 78 05 Na de Elektronik Sanayi ve Ticaret A fi ...