17
Using Functions:
Switch to SETUP MODE from NORMAL MODE with erasing all records:
CENTRAL UNIT is in NORMAL MODE when Function LED is Green and Status LEDs are OFF. Keep program
button pressed to Switch to SETUP MODE from NORMAL MODE with erasing all records. Status LEDs will
start to illuminate in sequence. DO NOT release the button when you see the status LEDs are all turned-
ON and Function LED is Blue ! Status LEDs will soon switched OFF one by one. Function LED will be turned
into RED after all LEDs turned off and all LEDs will be turned ON all together. Release the button and
CENTRAL UNIT will be restarted in SETUP MODE with deleted records.
Switch to NORMAL MODE from SETUP MODE:
CENTRAL UNIT is in SETUP MODE when Function LED is Green and Status LEDs are signalling in sequence.
In order to swhitch to NORMAL MODE , keep the program button pressed. Status LEDs will start to
illuminate in sequence. Release the button when you see the status LEDs are all turned-ON and Function
LED turned into RED from Green. CENTRAL UNIT is now in NORMAL MODE and it will be retarted in NORMAL
MODE.
First operation for CENTRAL UNIT:
Be careful to make sure that system cable is wired regarding to Diagram 1.19 and all ID depended devices
are set with uniqe IDs before the system is energised.
Turn-on the CENTRAL UNIT with mains voltage. Function LED will be RED colored and statue LEDs are all
turned on. Function LED will be turned into Blue and CENTRAL UNIT provides power transfer to other
units. After power transfer continues 10 seconds then CENTRAL UNIT will be started in NORMAL MODE
or SETUP MODE.
** CENTRAL UNIT is in NORMAL MODE when function LED is Green and Status LEDs are off.
Switch the CENTRAL UNIT into SETUP MODE with using
“Switch to NORMAL MODE from SETUP MODE”
function.
** CENTRAL UNIT is in SETUP MODE when Function LED is blue and status LEDs signalling in sequence.
CENTRAL UNIT will start to scan “switch based ID configured” devices (NDC, NVM-500MB/MC... etc)
automatically. Function LED will be turned into Green and Status LEDs continue to signal in sequence.
This stuation means CENTRAL UNIT is waiting data from “keypad based ID configured” devices. (8NDKC,
non-dip switched at back connection NVM-550MB/MC... etc.) When you complete ID configurastions from
“Keypad based” devices then use
“Switch to NORMAL MODE from SETUP MODE”
function to set
CENTRAL UNIT into NORMAL MODE.
In SETUP MODE, automatic scanning in proggress if Function LED is blue and status LEDs signals
in sequence. Do not attempt to switch CENTRAL UNIT into NORMAL MODE ! Wait to completing
scanning progress and function LED into Green !