DC24V
±
1 (from central unit)
0.4W (Min.), 10W (Max)
8 Wires
Full duplex
2 doorbell melodies, 2 phone melodies, 1 alarm melody
ABS and Metal
3,5” Color LCD
Calling time : 30 sec, Talking Time : 60 sec
95 (Heigth) x 170 (Width) x 24 (depth) mm
Audio - Brightness - Colour - Contrast
-20°C - +40°C
IP20
TECHNICAL CHARACTERISTICS
Operation voltage
Power consumption
Connection
Audio communication
Calling Melody
Material Content
Monitor
Monitor operating time
Dimensions
Settings
Operating temperature
Protection class
Functions
Communication with panel
Panel display
CCTV display
Communication with security
Door opener control
Communication with doorkeeper
Screen:
Monitor, colourful LCD
Audio Button:
Allows handsfree audio output and input with
speaker and microphone
Door Open Button
:
It is used to open entrance door.
Calling Doorkeeper :
It is used to call doorkeeper. After the
button is pressed and while the monitor is “ON” position If
button is pressed doorkeeper phone will ring. If the other side
does not end the phone call, after 60 seconds system
automatically ends the call. If there is more than one doorkeeper
in the system, in order to call first doorkeeper press the button
once. To call second doorkeeper press the button twice. If the
same process is repeated , other doorkeepers are called.
Maximum duration of pressing buttons should be 1 sn in these
combinations.
Panel and CCTV Display
:
Camera screen is displayed on
monitor screen for 30 seconds when the button is pushed, if
button is pushed before 30 seconds end; the other connected
panel and CCTV camera screens are displayed by sequence. if
the button is not pushed for 30 second, display is closed.
Security and Stairways Lighting Button :
It is used to call
security. After the button is pressed and while the monitor
is “ON” position If button is pressed security phone will ring.
If the either side does not end the phone call, after 60 seconds
system automatically ends the call. If there is more than one
security in the system, in order to call first security press the
button once. To call second security press the button twice.
MONITOR FUNCTIONS
NVM-350MC MONITOR
If the same process is repeated , other securities are called.
Maximum duration of pressing buttons should be 1 sn in these
combinations. The “ “ sign is used for door opener when the
monitor is at “Off” position.
Ring volume tuning:
Allows you to adjust ring volume tone.
Screen Settings:
Colour, brightness and contrast settings can
be done. When menu button is pushed, menu is displayed at
the bottom of the screen and after every push to the menu
button; brightness, colour and contrast is selected by sequence.
Selected value is set by "Up" and "Down" buttons. If the button
is not pushed in 10 seconds, menu is closed.
External video Input:
Additional camera connection shown in
Figure-8.2 flat door Camera can be monitored by when
somebody press doorbell button or can be monitored CCTV
button as shown in Figure-8.1. In case of using external video
input , 2nd group DIP switch must be set by 4th digit UP
position (”1”) as shown in Figure-8.2. If there is no external
video input this switch must be DOWN position (”0”).
75ohm video termination switch:
This switch must be “ON”
position as shown in Figure-8.2.
Note:
If an alarm dedector is connected to the system, all the
monitors will emerge householders by alarm event for 1 minute.
Door Open Button
Monitor ON-OFF
Calling security or stairways lighting button
Calling doorkeeper
Panel and CCTV display
FIGURE - 8.1
FIGURE - 8.2
Ending
resistance setting
+12V GND Video-in
Menu
Down
Up
Ring level Setting
Microphone
ON
12
3
4
5
6
7
8
12
3
4
ON
+24V
GND
V1
V2
A1
A2
D1
D2
INT BELL
GND
1. ID Swicth
2. ID Swicth
ON OFF
Flat door camera connection
ID settings:
You can make ID giving at NVM-350MC monitor by two seperate ID switches ( DIP SWITCHES). The first ID Switch and 2nd
ID switch is shown at Figure-8.2. First ID switch represents main ID number ( Flat number) and second ID switch indicates
slave montiors’ ID number ( if there are more than 1 monitor in same flat). If there will be used only one monitor in the flat
then the 2nd ID number must be “1” position.
Example: ID settings for 3 flats;
1st Monitor :
1. ID = 1, 2. ID = 1
2nd Monitor :
1. ID = 2, 2. ID = 1
3rd Monitor :
1. ID = 3, 2. ID = 1
Example: ID settings for 3 flats with 1 slave monitor for last monitor:
1st Monitor :
1. ID = 1, 2. ID = 1
2nd Monitor :
1. ID = 2, 2. ID = 1
3rd Monitor / master :
1. ID = 3, 2. ID = 1
3rd Monitor slave :
1. ID = 3, 2. ID = 2
39
Содержание GK-04-8
Страница 2: ......
Страница 50: ...45 FARKLI BA LANTI UYGULAMALARI BÖLÜM 10 ...
Страница 68: ......
Страница 116: ...45 DIFFERENT WIRING COMBINATIONS SECTION 10 ...
Страница 132: ...KK VBUS 7 8_140212_ENG_00 www na de com tr info na de com tr 0800 261 78 05 Na de Elektronik Sanayi ve Ticaret A fi ...