(Revised 2012-06-30) page 9 of 165
ENVIRONMENTAL SAFETY
WARNING:
Disconnect the power and allow to cool 5 minutes before touching.
ELECTRICAL SAFETY
WARNING:
Disconnect the power cable before removing any modules, or any enclosure panel.
WARNING:
Do not operate the unit with the any cover removed.
WARNING:
Properly ground the unit before connecting anything else to the unit. Units not properly grounded may result in a safety risk and
could be hazardous and may void the warranty. See the grounding technique section of this user manual for proper ways to ground the unit.
WARNING:
Do not work on equipment or cables during periods of lightning activity.
WARNING:
Do not perform any services on the unit unless qualified to do so.
WARNING:
Do not block the air vents.
WARNING:
Observe proper DC Voltage polarity when installing power input cables. Reversing voltage polarity can cause permanent damage
to the unit and void the warranty.
Installation Requirements
1.
WARNING:
Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known
to be non-hazardous.
2.
WARNING:
Install only in accordance with Local & National Codes of Authorities having jurisdiction.
3.
WARNING:
This equipment is suitable for use in Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations
Only.
4.
WARNING:
Explosion Hazard – Substitution of Components May Impair Suitability For Class I, Div. 2.
5.
WARNING:
Explosion Hazard – Do not remove SD Card unless power has been disconnected or the area is known to
be free of ignitable concentrations of flammable gases or vapors.
6.
WARNING:
Explosion Hazard – Do not remove Fiber Optic Transceivers unless power has been disconnected or the
area is known to be free of ignitable concentrations of flammable gases or vapors.
7.
Power must be supplied by an isolating source, and a
3.3 A max rated UL Recognized fuse must be installed
immediately before the unit.
8.
Class I, Div 2 installations require that all devices connected to this product must be UL listed for the area in which it is
installed.
9.
Only UL listed wiring with temperature ratings greater than 90°C permitted for Class I, Div 2 installations operating at
temperatures up to 70°C ambient.
10.
Limited Operating Voltage: 12-30V for Class I, Div 2 installations.
11.
Maximum operating voltage of power source shall not exceed 60 VDC including battery charging float voltage.
Содержание 7900 Series
Страница 37: ... Revised 2012 06 30 page 37 of 165 DHCP Server Setup Profiles Continued ...
Страница 40: ... Revised 2012 06 30 page 40 of 165 DHCP Server Setup IP Maps Continued ...
Страница 46: ... Revised 2012 06 30 page 46 of 165 DHCP Relay Local IP Setup Continued ...
Страница 52: ... Revised 2012 06 30 page 52 of 165 Ports Configuration Continued ...
Страница 88: ... Revised 2012 06 30 page 88 of 165 IGMP RFilter Continued Modifying rfilter port settings ...
Страница 96: ... Revised 2012 06 30 page 96 of 165 ...
Страница 124: ... Revised 2012 06 30 page 124 of 165 If a Configuration Device is present that is presented ...