(Revised 2012-06-30) page 102 of 165
N-Link – Configuration, Continued…
Complex N-Link Configuration (Example):
N-Ring #1
N-Ring AM
N-Link Slave
#1
N-Ring AM
N-Link Master
#1
Partner
Link #1
Control
Link #1
N-Rng
Manager
N-Link AC
N-Ring AM
N-Link AC
N-Ring AM
N-Ring
Auto
Member
Primary
Coupler
Link #1
Standby
Coupler
Link #1
N-Ring #2
N-Ring
Auto
Member
N-Ring AM
N-Link Slave
#2
N-Ring AM
N-Link Master
#2
Partner
Link #2
Control
Link #2
N-Rng
Manager
N-Link AC
N-Ring AM
N-Link AC
N-Ring AM
N-Ring
Auto
Member
Primary
Coupler
Link #2
Standby
Coupler
Link #2
N-Ring #3
N-Ring
Auto
Member
N-Ring AM
N-Link Slave
#3
N-Ring AM
N-Link Master
#3
Partner
Link#3
Control
Link #3
N-Rng
Manager
N-Link AC
N-Ring AM
N-Link AC
N-Ring AM
N-Ring
Auto
Member
Primary
Coupler
Link #3
Standby
Coupler
Link #3
N-Ring #4
N-Ring
Auto
Member
N-Ring
Auto
Member
N-Ring
Auto
Member
N-Rng
Manager
Configuration Notes:
The Master and Slave must be part of the N-Ring topology.
If using default configuration choices, the administrator only needs to configure the N-Link Master.
The N-Link Slave and both Coupler switches will auto-detect any needed configuration.
If not using default configuration choices, the administrator may also need to configure the Default
Coupler port on the N-Link Slave.
There must be a direct link between the Master and Slave Control ports. Use of media converters or
other switches is not supported.
There must be a direct link between the Master and Slave Partner ports. Use of media converters or
other switches is not supported.
There must be at least one other switch, besides the Master and Slave, that supports N-Link on the
N-Ring.
N-Link will only support a single point of failure. Multiple points of failure and misconfiguration
are not supported and may cause a network storm under some circumstances.
Configuration Steps to redundantly couple 2 N-Ring networks:
1.
Ensure the Coupler and Control cables are disconnected at this point.
2.
Get Both N-Rings working with a status of OK.
3.
Configure N-Link Slave: Ensure that the N-Link Slave is set to Auto Configure and select a Default
Coupler Port. Save Configuration.
4.
Configure N-Link Master: Select the Control and Coupler ports. Save the Configuration.
5.
Connect the Control Link cable. Ensure that the Slave switch status now shows a state of “Slave”
6.
Connect the Coupler Link cables.
7.
Check N-Link status by selecting the N-Link Status View page.
Содержание 7900 Series
Страница 37: ... Revised 2012 06 30 page 37 of 165 DHCP Server Setup Profiles Continued ...
Страница 40: ... Revised 2012 06 30 page 40 of 165 DHCP Server Setup IP Maps Continued ...
Страница 46: ... Revised 2012 06 30 page 46 of 165 DHCP Relay Local IP Setup Continued ...
Страница 52: ... Revised 2012 06 30 page 52 of 165 Ports Configuration Continued ...
Страница 88: ... Revised 2012 06 30 page 88 of 165 IGMP RFilter Continued Modifying rfilter port settings ...
Страница 96: ... Revised 2012 06 30 page 96 of 165 ...
Страница 124: ... Revised 2012 06 30 page 124 of 165 If a Configuration Device is present that is presented ...