6.
FMC
O
PERATION
6.1.
Front panel
Depending on the used FMC the front panel metalwork may not fit and needs to be reworked.
This is needed in case FMC with 8.5 mm stacking height are used that do not fit into the
standard front panel cut out which is made for 100 mm stacking height FMCs. Please contact
N.A.T. in case specialized front panel needs to be made.
6.2.
Supported FMC’s
All FMCs compliant to VITA 57.1 are supported, including region 1, 2, and 3 FMC modules.
VADJ and VIO_B_M2C are limited to 1.8V. Please check I/O 5.3.1 table for constraints to make
sure your FMC is supported.
6.3.
Installing a FMC Module
When applying a FMC module it could be necessary to remove or to untighten the front metal
in order for the FMC front to fit into the cut-out.
Figure 17
–
Installing FMC Module Part 1
After fitting the FMC module to the carrier, the front panel needs to be restored.