EV-030
Rev. 07 – 2008
English
48
Troubleshooting
FAULT
CAUSE
CORRECTIVE ACTION
Though UP or DOWN
keys are pressed, the
instrument doesn't
receive any signal from
the magnetic sensor for
more than 5 seconds.
Check the sensor electric
connections.
Check if sensor operates
properly. If not, replace it.
Check the position of
sensor and magnet on
gipsy and their distance
(3 mm).
Check the operation of
electric installation or
anchor windlass.
The instrument’s power
supply voltage is lower
than 10V.
Verify the battery charge
or operation of the
electrics system.