57
Installation’s Instructions
The burner’s installation should be carried out by authorized technicians-installers
according to the instructions below.
Authorized electrician should carry out the electrical connection
Chimney’s installation should follow the regulations of
ELOT 447 DIN 4705
The boiler must operate with minimum 2.5 m vertical chimney and maximum 2
direction changes. For every additional change of direction or for every additional 1m
horizontal section, 1.5m of vertical chimney must be added.
It is forbidden the use of flexible exhaust pipe for the chimney
For indoor installation it is absolutely necessary the connection of fresh air supply
It is absolutely obligatory the use of sprinkler in the boiler room.
It is absolutely obligatory the use of anode protection when the water circuit has
non- similar materials.
It is obligatory for the hydro stoves to install a safety valve (3 bar) on the hydraulic
system and to ensure that the water circuit has been ventilated.
Attention to the connection of the room thermostat – Not 220 V voltage-
Before the stove’s ignition the fuel’s quality should be checked (pellet/briquette/
wood)
Solid fuels should be stored in dry and covered place.
Obligatorily, the first ignition must be carried out of an authorized/licenced installer
who will be responsible for the function of the stove too.
Stove’s installation and maintenance should be carried out only from authorized
technicians and installers.
The company bears no responsibility for faulty installation and non-compliance with
the installation instructions and the use of non-certified fuel.
A study and calculations of thermal losses must be carried out by an experienced
engineer or a certified installer in order to choose the correct model/type of the
stove. The engineer or the installer is responsible for the selection.
MIK EUROPE-MYTHERM Industry guarantees the stove and is obliged by law to cover
construction and material failures in accordance with the guarantee, to maintain
stock of spare parts, to train installers with seminars and to provide telephone
support to them and only to them, whenever
there is a need for it
.
The company/manufacturer does not install, maintain, and repair the devices in the
user’s place. Neither can do that by telephone or change setting by phone. This can
cause further damages. The telephone assistance provided by the company does not
take the place of the installer and it is the user who bears responsibility.
The company produces and provides for sale products according to European
regulation ISO-CE-EN. It is absolutely obligatory for the client to accept and comply