46
The speed of the exhaust fan as well as the time on of the feeder motor in
the IGNITION process are preset and the control is only possible through the
MENU > SETTINGS > RECIPE > Air Temp
.(for the combustion airflow setting)
and
> RECIPE > Pellet Temp
.(for the time on setting) in total by fluctuation
rate.
The time of initial feeding
TECHNICAL MENU > IGNITION MENU > Pre-
Startup Duration
2.
The warm-up time of the resistance during ignition process
TECHNICAL
MENU > IGNITION MENU > Pre-Startup Duration 1.
The burner has
600 sec
to achieve the preset exhaust gas temperature
(
TECHNICAL MENU >IGNITION MENU > Fumes Temp. ON.
If at the
predetermined time the machine exceeds the predetermined temperature
then it enters the next phase of combustion balancing at a predetermined
time by
TECHNICAL MENU > IGNITION > Fire On Duration.
The goal is to
pass to the next cumbastion level of normal operation
ON
without unburned
pellet. If it fails to exceed the preset temperature
ON
then the display shows
A 01
ignition failed. To reset the stove we press the key 1 at the control panel
(indication
info
).
The display panel shows information about the error and the
info
position
displays the word
esc
. Press second time the
key 1
to appear
info
in the
esc
position. Then, we press and hold the key 5 until a beep sounds and the
display pannel shows
“check is going on”.
Within a short period of time, the
display shows indication about how to continue the operation. (
OFF / SHUT
DOWN
) and reset the device by pressing the
key 5
(On / Off).
For the first ignition we activate the auger feeder from
MENU>Settings>Charge Pellet. When the auger «uploads» pellet
and drops it into the pot we deactivate the function and we can
start up the device.