5 - Troubleshooting

Issue

Possible Cause

Solution

Machine is not 
turning on.

Power cord unplugged.

Plug the power cord into a grounded 20 amp 
outlet.

Circuit breaker tripped in building.

Reset breaker in building.

Faulty switch or power cord.

Contact a Mytee Service Center.

Poor solution 
flow.

Jet is clogged.

Unclog the jet by removing and soaking in a vin-
egar and water solution. Scrub with a soft brush. 
Repeat if necessary.

Blockage or clog in solution line.

Run System Maintainer through machine.

Pump contin-
uously runs/
pulses.

Leak in solution line between pump and clean-
ing tool.

Find leak and repair or replace hose if neces-
sary.

Pump switch failure. This can be caused by 
various issues:

Contact a Mytee Service Center.

•  Nozzle tip clogged or too small, causing rapid 

switch cycling.

•  Check valve failure between pump and heater 

causing hot water to return to pump and dam-
age switch.

•  Pump inlet port is cracked causing pump to 

suck in air.

•  Damaged pump switch housing.

Water is not 
pumping out of 
machine.

Vapor lock from turning on heater before pump.

Turn off the heater and allow the machine to 
cool completely. After machine has cooled, 
follow the machine startup procedure in section 
2.4 of this manual.

Vacuum/pump/
heater not turn-
ing on.

Bad power switch.

Check power switch by transferring wires from 
the switch in question to another switch. See if 
that switch turns on the component in question. 
Replace switch if necessary.

Vacuum not pro-
ducing suction.

Vacuum tank is full.

Empty vacuum tank.

Vacuum hose blockage.

Check for blockages in vacuum hoses inside 
and outside machine.

Blows water out 
exhaust.

Foam building up inside vacuum tank.

Use a defoaming solution in vacuum tank or use 
low foam or non foaming detergent/shampoo.

Water is not 
getting hot.

Automatic (black) sensor failure causing manual 
(white) sensor to trip.

Reset the manual (white) sensor by pressing the 
small button on it. If the manual sensor contin-
ues to trip, replace the automatic (black) sensor 
(part no. E573).

Содержание 8070 Lite

Страница 1: ...Mytee Lite Model 8070 REV 6 3 21 User Manual 13655 Stowe Dr Poway CA 92064 P 858 679 1191 F 858 726 6005 www mytee com...

Страница 2: ...use Neglecting your machine abusing it or not operating it properly can void its warranty and prevent the machine from performing to the quality and standard you d expect out of the Mytee line If you...

Страница 3: ...7 1 4 Mytee Lite Rear View 8 1 5 Switch Plate 9 Machine Operation 10 2 1 Powering the Mytee Lite 10 2 2 Connecting Hoses Cleaning Tools 10 2 3 Filling the Solution Tank 10 2 4 Operating the Mytee Lit...

Страница 4: ...g a plug this wire must be attached to only the grounding pin DO NOT use extension cords Please Note for America use only Parts and Service Please contact a Mytee service personnel or Mytee authorized...

Страница 5: ...be used as a toy Close attention is necessary when used by or near children 11 Do not use in areas where flammable or combustible material may be present 12 Do not leave the unit exposed to harsh wea...

Страница 6: ...I 120 Pump GPM 1 3 Heater 1 000 watt 210 F max Power Consumption 19 amps 115V Machine Weight 48 lbs Machine Dimensions With handle 33 x 12 x 36 5 Without handle 18 x 12 x 28 5 Power Cord Single 25 12...

Страница 7: ...Handle 2 Recovery Tank 3 10 Wheels 4 Quick Disconnect 5 Solution Tank Drain 6 Solution Tank 7 Faucet Fill Hose 8 Bucket Fill Opening 9 Cuff Lynx Hose Connection 10 Recovery Tank Lid 1 3 Mytee Lite Fro...

Страница 8: ...8 1 At a Glance 1 3 Locking Front Casters 2 25 12 3 Power Cord 3 Switch Plate 4 Opening Latch 5 Recovery Tank Drain Hose 6 Storage Basket 1 4 Mytee Lite Rear View 1 2 3 4 5 6...

Страница 9: ...9 1 At a Glance 1 5 Switch Plate 1 Vacuum Switch Activates the vacuum motor 2 Pump Switch Activates the solution pump 3 Heater Switch Activates the heater 1 2 3...

Страница 10: ...ck connect fitting on the base of the machine To connect pull back the flange on the female fitting from the hose and slide onto the male fitting on the machine Release to lock fittings together 2 3 F...

Страница 11: ...d e g while spraying with cleaning tool or right at startup If the pump is continuously running or pulsing there may be an issue with the pump pressure switch See the Troubleshooting section of this m...

Страница 12: ...of the vac uum stack in the recovery tank This filter should be checked and cleaned after each use 3 2 System Maintainer Regular flushing of the solution system with Mytee Sys tem Maintainer keeps yo...

Страница 13: ...13 4 Available Accessories 8400M Mytee Dry Upholstery Tool 8400 4 Stainless Steel Upholstery Tool 8700 Crevice Tool 8390EZ 10 Single Jet Carpet Cleaning Wand...

Страница 14: ...inlet port is cracked causing pump to suck in air Damaged pump switch housing Water is not pumping out of machine Vapor lock from turning on heater before pump Turn off the heater and allow the machin...

Страница 15: ...NOTES...

Страница 16: ...Mytee LLC 13655 Stowe Dr Poway CA 92064 www mytee com 2021 Mytee LLC Printed in the USA...

Отзывы: