5 - Troubleshooting
Issue
Possible Cause
Solution
Machine is not
turning on.
Power cord unplugged.
Plug the power cord into a grounded 20 amp
outlet.
Circuit breaker tripped in building.
Reset breaker in building.
Faulty switch or power cord.
Contact a Mytee Service Center.
Poor solution
flow.
Jet is clogged.
Unclog the jet by removing and soaking in a vin-
egar and water solution. Scrub with a soft brush.
Repeat if necessary.
Blockage or clog in solution line.
Run System Maintainer through machine.
Pump contin-
uously runs/
pulses.
Leak in solution line between pump and clean-
ing tool.
Find leak and repair or replace hose if neces-
sary.
Pump switch failure. This can be caused by
various issues:
Contact a Mytee Service Center.
• Nozzle tip clogged or too small, causing rapid
switch cycling.
• Check valve failure between pump and heater
causing hot water to return to pump and dam-
age switch.
• Pump inlet port is cracked causing pump to
suck in air.
• Damaged pump switch housing.
Water is not
pumping out of
machine.
Vapor lock from turning on heater before pump.
Turn off the heater and allow the machine to
cool completely. After machine has cooled,
follow the machine startup procedure in section
2.4 of this manual.
Vacuum/pump/
heater not turn-
ing on.
Bad power switch.
Check power switch by transferring wires from
the switch in question to another switch. See if
that switch turns on the component in question.
Replace switch if necessary.
Vacuum not pro-
ducing suction.
Vacuum tank is full.
Empty vacuum tank.
Vacuum hose blockage.
Check for blockages in vacuum hoses inside
and outside machine.
Blows water out
exhaust.
Foam building up inside vacuum tank.
Use a defoaming solution in vacuum tank or use
low foam or non foaming detergent/shampoo.
Water is not
getting hot.
Automatic (black) sensor failure causing manual
(white) sensor to trip.
Reset the manual (white) sensor by pressing the
small button on it. If the manual sensor contin-
ues to trip, replace the automatic (black) sensor
(part no. E573).