iVECTOR Heater/Cooler

12.0

12.2  Operating Modes

Use (

) and (

) keys to choose from the following parameters.

A function is selected when the icon is surrounded by    .

Function

Adjustment

Description

Availability

Easy

Full

Control Operation Setup

The unit must be programed for operation 
in heating only, cooling only or heating and
cooling.

Control Operation Setup

Scroll to the Fixed Fan mode      , and then
press on the (    ) key.
Use (+) or (-) keys to choose from
the following:

Nod (Mode)  HOt 

for heating.

Nod (Mode) COLd

for cooling.

Nod (Mode)  AUtO

for heating and cooling.

Press (OK) to confirm.

Fixed Fan Setting

F1, F2, F3 gives fan speed 1,2 or 3 respectively
with no temperature control. A1, A2, A3 gives
fan speed 1,2 or 3 respectively in heating only 
if the water temperature 

32°C.

Use (+) or (-) to select and press (OK) to confirm.
(Note the fan speed symbol will only appear
when the fan is running).

Comfort Setting

Provides room temperature control with 
automatic fan speed adjustment according to
difference between actual and set temperature.
The fan operates when water 

32°C in heating

or 

15°C cooling.

Press (OK) to view the set temperature.
Use (+) or (-) to adjust the required room 
temperature. Default setting is 21°C in Heating.

Automatic Setting

The unit will run according to one of the 9 
preset timed programs, or one of the 4 user 
defined programs.

See section 12.5 for program options 
and setup. 
Press (OK) to view the actual set 
temperature (Comfort or Set-back).

Night Set-back Setting

Provides room temperature control with 
automatic fan speed adjustment according 
to difference between actual and night set-back 
temperature.

Press (OK) to view the set temperature.
Use (+) or (-) to adjust the required room 
temperature. Default setting is 19°C in 
Heating.

Holiday Function

Provides frost protection or overheat protection
during periods of absence (holiday). The control
will count down the time to “00” after which
control is resumed in Auto setting. For frost 
protection the set temperature is 7°C. 
For overheat the set temperature is 30°C.

Select       and is       displayed. 
Use the (+) and (-) to adjust the duration.
(In hours “H” if below 24H and then in
days “d”). 
Use the (-) key to interrupt this period
and adjust the duration on “no”.

Power On/Off

Turns unit on/off.

Press (OK) to turn the power on or off.

Set Clock Menu

Displays time in 12h or 24h format.

Press (OK)
Use the (+) and (-) keys to set the minutes. 
Press (OK)
Use the (+) and (-) keys to set the hours. 
Press (OK)
Use the (+) and (-) to set the days. Press (OK).

Program Menu

Provides choice from 9 pre-programed and 
4 user defined timed programs.

See section 12.5 for full details.

No

Yes

Yes

Yes

Yes

Yes

No

Yes

No

Yes

No

Yes

Yes

Yes

Yes

Yes

No

Yes

Auto

P

24197 iVector Installation Guide V2_Layout 1  28/11/2011  14:49  Page 16

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818   

Содержание iV080

Страница 1: ...nd user Part Number 1370067 Issue 1 heatingthroughinnovation iVECTOR Heater Cooler Models iV080 iV100 iV120 iV140 iV160 01 10 2011 ISSUE 1 24197 iVector Installation Guide V2_Layout 1 28 11 2011 14 49...

Страница 2: ...0 Control System Set up and Operating Instruction 13 12 1 Unit Operation 13 12 2 Operating Modes 15 12 3 Installer s Set up Parameters 16 12 4 Building Management System Input Set up 16 12 5 Program...

Страница 3: ...t in such a way that it is suitable for intended use and predictable misuse A number of elements need to be taken into consideration including the fixing method used to secure it to the wall the type...

Страница 4: ...fort mode when the room temperature is significantly lower than the preset temperature Note It is also possible to electronically remove the highest fan speed from the functionality of this unit via t...

Страница 5: ...tents for concealed shipping damage Tools required Manual Warranty Exploded View Grill Grill hinge Outer casing Filter Side cover Control panel Chassis 1 2 3 5 4 Model A B Dimensions mm iV080 800 503...

Страница 6: ...ver until connection to system and connection to electrical supply has been completed 1 2 3 4 5 6 24197 iVector Installation Guide V2_Layout 1 28 11 2011 14 49 Page 7 For latest prices and delivery to...

Страница 7: ...ors so that the pipe work can more easily be routed past the condensate collector Dimensions 2 pipe 7 0 8 0 Pipe Routing Options 2 pipe connection Note 1 The flow pipe should be connected to the botto...

Страница 8: ...carried out by a qualified electrician in accordance with current regulations l This unit is supplied with factory fitted test leads Remove these and discard l A fused electrical spur with a maximum...

Страница 9: ...pages 10 11 After making the electrical connections replace the side cover to the control box 1 Remove x 2 screws to access control panel 3 Routing cable 2 Remove control panel cover 8 0 9 0 24197 iVe...

Страница 10: ...2 PIPE BL 2 pipe 0 valve Supply 230V 50Hz 24V 50Hz 24V DC Supply 230V 50Hz POWER BOARD CONTROL BOARD WATER SENSOR 2 PIPE AIR SENSOR R W Y T T M M Lo Med Hi Y W R BR FAN TRANSFORMER L N BL 2 pipe 1 va...

Страница 11: ...d vent air from the heat exchanger l Check for leaks at pipe connections 2 l Refit the outer casing and secure with the 2 screws l Switch on the electrical supply l Check the operation of the unit by...

Страница 12: ...del Sound Power LwA dB iV60x080 31 9 44 8 55 24 8 37 7 47 9 iV60x100 34 1 42 9 55 27 35 8 47 9 iV60x120 31 1 44 7 58 8 24 40 5 51 7 iV60x140 32 42 6 61 9 24 9 35 5 54 8 iV60x160 34 1 42 1 63 4 27 35 5...

Страница 13: ...mode Refer to section 12 2 for details Setup Parameters Refer to section 12 3 for details Select Clock Set Time Full Mode Select Comfort Setting Set room temperature to desired setting default 21 C F...

Страница 14: ...5 seconds This action can be repeated to revert back to Easy mode 1 Heating indicator 2 Cooling indicator 3 Temperature symbol when this is displayed the current room temperature is displayed 4 Fan sp...

Страница 15: ...r defined programs See section 12 5 for program options and setup Press OK to view the actual set temperature Comfort or Set back Night Set back Setting Provides room temperature control with automati...

Страница 16: ...will flash and the system stops BMS control Parameter Name Default Setting Description Alternative Setting Select temperature scale dEG C F Select the hour format 00 00 24H 12H Fan pulse will switch...

Страница 17: ...Built in programs description P1 Morning Evening Weekend P2 Morning Afternoon Evening Weekend P3 Day Weekend P4 Evening Weekend P5 Morning Evening Bathroom P6 Morning Afternoon Weekend P7 7h 19h Offi...

Страница 18: ...t and right arrows to scroll through the inputs outputs from relays air sensor water sensors BMS inputs and screen to check as necessary Note The control will revert back to the main menu after 1 minu...

Страница 19: ...r cleaning as shown below See spare parts list section if replacement filters are needed Remove the old filter Place the new filter 15 0 Spare Parts Accessories Part No Size mm iV080 iV100 iV120 iV140...

Страница 20: ...rts and technical help on all Convector products are available from MYSON Service MYSON Eastern Avenue Team Valley Gateshead Tyne Wear NE11 0PG UK T 0845 402 3434 F 0191 491 7568 sales myson co uk www...

Отзывы: