12
iVECTOR Heater/Cooler
11.0 Technical Data
The iVECTOR should be sized based on “normal” outputs.
Model
Δ
T50
(75-65-20)
Δ
T20
(45-35-20)
Heating
(
watts
)
Cooling
(
watts
)
Condition 7-12-27
Total
Sensible
Normal
1824
704
707
527
Medium
2556
935
1126
829
Boost
3682
1358
1648
1227
Normal
2606
905
1011
753
Medium
3632
1283
1600
1178
Boost
5149
1883
2304
1716
Normal
3224
1086
1250
931
Medium
4448
1804
1960
1442
Boost
6521
2376
2918
2173
Normal
3842
1267
1490
1110
Medium
5265
2324
2320
1707
Boost
7894
2869
3533
2631
Normal
4460
1448
1729
1288
Medium
6082
2845
2679
1972
Boost
9266
3363
4147
3088
iV60x080
iV60x100
iV60x120
iV60x140
iV60x160
Performance Data
Weight, Water Content and Motor Power
Noise Levels
Noise levels tested in accordance with ISO 3741.
Model
Sound Power LwA (dB)
iV60x080
31.9
44.8
55
24.8
37.7
47.9
iV60x100
34.1
42.9
55
27
35.8
47.9
iV60x120
31.1
44.7
58.8
24
40.5
51.7
iV60x140
32
42.6
61.9
24.9
35.5
54.8
iV60x160
34.1
42.1
63.4
27
35
56.3
Normal
Medium
Boost
Sound Pressure (dBA)
Normal
Medium
Boost
Model
Motor
Power (w)
Water
Content (l)
Unpacked
Weight (kg)
Dimensions
Model
Nominal Height
(mm)
Depth
(mm)
Length
(mm)
iV60x080
600
153
800
iV60x100
600
153
1000
iV60x120
600
153
1200
iV60x140
600
153
1400
iV60x160
600
153
1600
iV60x080
32
0.66
22.8
iV60x100
35
0.92
27.7
iV60x120
45
1.19
32.5
iV60x140
53
1.45
37.5
iV60x160
65
1.72
42.6
All
iVECTOR
models require an electrical supply of 220-240V –
50Hz fused at 3A.
Electrical Data
Fan Speed
Relative Humidity:
Sensible cooling at 50%.
* For BTUs multiply Watts by 3.412.
24197 iVector Installation Guide V2_Layout 1 28/11/2011 14:49 Page 13
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818