18
LED
Error
code
Issue
Possible reason
Solution
E5
Press transmitter, but no gate
movement.
1) STOP swtich is open.
1) Check if STOP switch is open or damaged.
2) STOP switch is not connected.
2) Check if STOP switch is disconnected. If yes, then reconnect
STOP switch or change the respective Input setting to other value.
E7
Press transmitter, but no gate
movement.
Control board amplifier for Motor 1 fail.
Switch off power for 20 seconds and reset to check if control board
recovers. If not, change control board.
E8
Press transmitter, but no gate
movement.
Control board amplifier for Motor 2 fail.
Switch off power for 20 seconds and reset to check if control board
recovers. If not, change control board.
E9
Press transmitter, but no gate
movement.
Control board memory mistake.
Switch off power for 20 seconds and reset to check if control board
recovers. If not, change control board.
F1
Motor 1 stop and reverse
during open or close.
Motor 1 is blocked.
Check and remove obstruction. Clean gate.
F2
Motor 2 stop and reverse
during open or close.
Motor 2 is blocked.
Check and remove obstruction. Clean gate.
F3
Motor 1 stop and reverse
during open or close.
Motor 1 stall or speed sensor is damaged.
Check if motor 1 stalled or speed sensor is damaged.
F4
Motor 2 stop and reverse
during open or close.
Motor 2 stall or speed sensor is damaged.
Check if motor 2 stalled or speed sensor is damaged.
F5
Press transmitter, but motor
has no action.
Radio module fail.
Switch off power for 20 seconds and reset to check if control board
recovers. If not, change control board.
F6
Gate reverse during closing. Low battery power.
Charge battery.
F7
Press transmitter, but no gate
movement.
Control board damaged.
Switch off power for 20 seconds and reset to check if control board
recovers. If not, change control board.
F9
Press transmitter or push
button, but motor has no
action.
AP menu is reset to factory default.
Relearn limits.
LE
Motor stops suddenly.
Press C button during limit learning.
Relearn limits.
9. ERROR CODES
CHAA250EVC
Input Voltage
VAC
220-240
Input frequency
Hz
50/60
Motor Voltage
VDC
24V
Standby consumption
(without accessories)
W
3.2
Motor Rated Power
W
100W (CHAA250-24P)
50W (CHAA250-24S)
Rated Load
Nm
72,4
Maximum Torque
Nm
200
Cycles per hour
5
Max. cyles per day
20
Max. wing width / weight
m / kg
1.5m / 200kg
2.0m / 150kg
2.5m / 100kg
Max. opening angle
120°
Time to open to 90°
s
13-15
End Limit System
Encoder with hard stops
Operating Radio Frequency
Sending Power
MHz
RX 433MHz
(433.30MHz, 433.92MHz, 434.54MHz)
RX 868MHz
(868.30MHz, 868.95MHz,
869.85MHz)
TX 865.125MHz, 865.829MHz,
866.587MHz
<10mW
Code
S 2.0
Max. nr of remotes
180
Max. nr. of keypads
4
Max. nr. of myQ devices
16
CHAA250EVC
External accessory power
24VDC - max. 500mA
Flahing lamp connector
24VDC - max. 500mA
E-Lock /Magnetic lock conenctor
24VDC - max. 500mA
External relay
24VDC - max. 500mA
Safety edge
8,2 kOhm
Max. nr. of IRs
3
Max. nr. of external inputs
3
Battery back-up unit
2 x 12V, 2.2Ah batteries model 490EV
Ingress Protection Motor
IP
44
Noise Level
dB
< 70 db(A)
Working temperature
°C
-20°C to +55°C
Weight (kit)
Kg
20
Transmitter Frequency
TX4REV-F
868MHz (868.30MHz, 868.95MHz,
869.85MHz)
Sending power
<10mW
Battery
CR2032 3V
10. TECHNICAL DATA