The MyGate Q71S Control Board Installation Manual : Printed 11/02/2013 13:16
9
To Use in Closing Cycle
To connect power to Transmitter Unit
Use 1 core wire to connect AC+ on photocell
Transmitter Unit (TX) to Terminal 8.
Use 1 core wire to connect AC- on photocell
Transmitter Unit (TX) to Terminal 9
To connect power to Receiver Unit
Use 1 core wire to connect AC+ on photocell
Receiver Unit (RX) to Terminal 8
Use 1 core wire to connect AC- on photocell
Receiver Unit (RX) to Terminal 9
To connect the relay function to Control Board
Use 1 core wire to connect 3
rd
terminal
(looking from left to right) on photocell
Receiver Unit (RX) to Terminal 15
Use 1 core wire to connect 4th terminal
(looking from left to right) on photocell
Receiver Unit (RX) to Terminal 14
IMPORTANT: Please place a link between terminals 16 and 17
To Use in Opening Cycle
To connect power to Transmitter Unit
Use 1 core wire to connect AC+ on photocell
Transmitter Unit (TX) to Terminal 8
Use 1 core wire to connect AC- on photocell
Transmitter Unit (TX) to Terminal 9
To connect power to Receiver Unit
Use 1 core wire to connect AC+ on photocell
Receiver Unit (RX) to Terminal 8
Use 1 core wire to connect AC- on photocell
Receiver Unit (RX) to Terminal 9
To connect the relay function to Control
Board
Use 1 core wire to connect 3
rd
terminal
(looking from left to right) on photocell
Receiver Unit (RX) to Terminal 17
Use 1 core wire to connect 4th terminal
(looking from left to right) on photocell
Receiver Unit (RX) to Terminal 16
IMPORTANT: Please place a link between terminals 14 and 15