background image

                                 11_2016

h min= 15 cm

h max= 60 cm

myAster 3  A=150 B=150    
myAster 4  A=200 B=200   
myAster 5  A=250 B=250
myAster 6  A=300 B=300

150 mm

90°

myAster 3   = max 125 mm

myAster 4  = max 175 mm

myAster 5  = max 225 mm

myAster 6  = max 275 mm

D

A

C

B

minimo 

3.4  INSTALLING THE OPERATOR

The kit is supplied with a right and a left hand motor and are specific. Ensure you are mounting the correct 

handed motor to the leaf. See picture C. Make sure there is a mechanical stop (

B

) for opening and closing. 

B

 = mechanical ground stops

3.4.1. QUOTES FROM GROUND

The operator has to be fitted keeping a height from ground between 

40 and 50 cm

. See picture D.

If the gate is particularly light, fit the operator as closer as possible to gate centerline.

3.4.2. PILLAR BRACKETS – How to determine fixing dimensions

The ideal approach is to fix the brackets complying with the measures A and B as indicated in the below table 

for an opening 

angle of 90°

 (picture E).

Pic. C

Pic. D

Pic. E

right

Motor

left

Motor

Содержание myAster 3

Страница 1: ...01_17 myAster AUTOMATION FOR SWING GATES Installation manual...

Страница 2: ......

Страница 3: ...TION 3 1 Preliminary checks 3 2 Tools and materials not included 3 3 Wiring 3 4 Installing the operator Quotes from ground Pillar brackets 4 MANUAL RELEASE 5 MAINTENANCE 6 WARRANTY 7 PHASING OUT AND D...

Страница 4: ...erefore forbidden Do not allow children to play with the fixed command devices or in the gate s area of operation Keep any remote control devices i e transmitters away from the children as well Keep t...

Страница 5: ...40 115V 60Hz 2 0 2 3A 300W 30 F 150 C 3000N 44 1700 rpm 110 deg 14 300Kg 2 00m 40 V A W F C N IP rpm deg s Kg m 410 710 Motor power supply Max draw Power Capacitor Thermal protection Adjustable thrus...

Страница 6: ...3 11_2016 3 2 TOOLS AND MATERIALS NOT INCLUDED brick 18mm concrete 15mm inox alu tubular stainless steel PILLARS AND WALLS LEAF stainless steel alu wood 3 3 3 3 3 3 3 3 2 2 2 2...

Страница 7: ...rotect both the gate control panel and the house main fuse box A 6A automatic breaker or a 16A single phase breaker complete with fuses shall be suitable Make sure you have suitable tubing and conduit...

Страница 8: ...otor to the leaf See picture C Make sure there is a mechanical stop B for opening and closing B mechanical ground stops 3 4 1 QUOTES FROM GROUND The operator has to be fitted keeping a height from gro...

Страница 9: ...mi meccanici Fig D 3 4 1 DETERMINAZIONE ALTEZZA DI FISSAGGIO ATTUATORI L altezza di fissaggio consigliata compresa tra 40 50 cm fig E In caso di cancelli con struttura leggera tenere l attuatore pi vi...

Страница 10: ...t T1 and place the pivot pin PR1 though the holes Keep the pivot pin PR1 oriented downward See picture L 3 4 4 GATE BRACKET S3 To determine the position of bracket S3 Put the gate in closing position...

Страница 11: ...esponsibility of who installs the system Under no circumstances and in no way Proteco Srl will be liable for damages including any loss of profits savings or other incidental or consequential damages...

Страница 12: ...electrical and electronic equipment The above listed products are delivered limitedly to the applicable parts according to the following standards EN 12453 EN 12445 EN60335 1 EN60335 2 103 Industrial...

Страница 13: ...by Proteco S r l Via Neive 77 12050 CASTAGNITO CN ITALY Tel 39 0173 210111 Fax 39 0173 210199 info proteco net www proteco net...

Отзывы: