background image

2

myAster 3: 

myAster 4:

20

70

99

169

myAster 3: 

myAster 4: 

myAster 5: 

    510

    610

88

55 63

myAster 6: 

88

20

myAster 5: 

myAster 6:

myAster 3

myAster 4

myAster 5

myAster 6

24Vdc
0,5-0,75A
50W
--
--
2500N
44
1600 rpm
110°deg
20”
250Kg
2,50m
80%

230V~50Hz
1,2-2A
280W
8µF
150°C
2800N
44
1400 rpm
110°deg
22”
350Kg
2,75m
40%

115V~60Hz
2,0-2,3A
300W
30µF
150°C
3000N
44
1700 rpm
110°deg
18”
250Kg
2,75m
40%

24Vdc
0,5-0,75A
50W
--
--
2500N
44
1600 rpm
110°deg
25”
150Kg
3,00m
80%

230V~50Hz
1,2-1,7A
280W
8µF
150°C
2800N
44
1400 rpm
110°deg
27”
250Kg
3,5m
40%

115V~60Hz
2,0-2,3A
300W
30µF
150°C
3000N
44
1700 rpm
110°deg
22”
200Kg
3,5m
40%

230V~50Hz
1,2-1,7A
280W
8µF
150°C
2800N
44
1400 rpm
110°deg
32”
250Kg
4m
40%

24Vdc
0,5-0,75A
50W
--
--
2500N
44
1600 rpm
110°deg
15”
275Kg
2,00m
80%

230V~50Hz
1,2-1,7A
280W
8µF
150°C
2800N
44
1400 rpm
110°deg
17”
350Kg
2,00m
40%

115V~60Hz
2,0-2,3A
300W
30µF
150°C
3000N
44
1700 rpm
110°deg
14”
300Kg
2,00m
40%

V

A

W

µF

N
IP

rpm
deg

s

Kg

m
%

410

710

Motor power supply

Max draw.

Power

Capacitor

Thermal protection 

Adjustable thrust

Protection rating

Revolutions

Opening angle 

Opening time (90°)

Leaf weight

Leaf length

Duty cycle

2.2  TECHNICAL FEATURES

3.   INSTALLATION

3.1  Preliminary checks

Before installing make sure:

Weight, dimensions and gate construction are proper for the operator you intend to buy

Proper mechanical stops are already in place

The gate swings freely

The opening of the automated gate is not an entrapment hazard as regards any surrounding fixed parts and 

there is sufficient space for manual release

Any lawn watering devices will not wet the gearmotor from the bottom up

The earth cable is properly connected

Do not install onto gates on either an upward or downward slope 

(i.e. that are not on flat, level ground)

2.3  OPERATOR DIMENSIONS

  Closed = 665 /  Open = 980

Closed = 765 /  Open = 1180

   Closed = 865 /  Open = 1380

   Closed = 965 /  Open = 1580

Содержание myAster 3

Страница 1: ...01_17 myAster AUTOMATION FOR SWING GATES Installation manual...

Страница 2: ......

Страница 3: ...TION 3 1 Preliminary checks 3 2 Tools and materials not included 3 3 Wiring 3 4 Installing the operator Quotes from ground Pillar brackets 4 MANUAL RELEASE 5 MAINTENANCE 6 WARRANTY 7 PHASING OUT AND D...

Страница 4: ...erefore forbidden Do not allow children to play with the fixed command devices or in the gate s area of operation Keep any remote control devices i e transmitters away from the children as well Keep t...

Страница 5: ...40 115V 60Hz 2 0 2 3A 300W 30 F 150 C 3000N 44 1700 rpm 110 deg 14 300Kg 2 00m 40 V A W F C N IP rpm deg s Kg m 410 710 Motor power supply Max draw Power Capacitor Thermal protection Adjustable thrus...

Страница 6: ...3 11_2016 3 2 TOOLS AND MATERIALS NOT INCLUDED brick 18mm concrete 15mm inox alu tubular stainless steel PILLARS AND WALLS LEAF stainless steel alu wood 3 3 3 3 3 3 3 3 2 2 2 2...

Страница 7: ...rotect both the gate control panel and the house main fuse box A 6A automatic breaker or a 16A single phase breaker complete with fuses shall be suitable Make sure you have suitable tubing and conduit...

Страница 8: ...otor to the leaf See picture C Make sure there is a mechanical stop B for opening and closing B mechanical ground stops 3 4 1 QUOTES FROM GROUND The operator has to be fitted keeping a height from gro...

Страница 9: ...mi meccanici Fig D 3 4 1 DETERMINAZIONE ALTEZZA DI FISSAGGIO ATTUATORI L altezza di fissaggio consigliata compresa tra 40 50 cm fig E In caso di cancelli con struttura leggera tenere l attuatore pi vi...

Страница 10: ...t T1 and place the pivot pin PR1 though the holes Keep the pivot pin PR1 oriented downward See picture L 3 4 4 GATE BRACKET S3 To determine the position of bracket S3 Put the gate in closing position...

Страница 11: ...esponsibility of who installs the system Under no circumstances and in no way Proteco Srl will be liable for damages including any loss of profits savings or other incidental or consequential damages...

Страница 12: ...electrical and electronic equipment The above listed products are delivered limitedly to the applicable parts according to the following standards EN 12453 EN 12445 EN60335 1 EN60335 2 103 Industrial...

Страница 13: ...by Proteco S r l Via Neive 77 12050 CASTAGNITO CN ITALY Tel 39 0173 210111 Fax 39 0173 210199 info proteco net www proteco net...

Отзывы: