section 7 ~ myerson DuraFlex partial
injection procedure
The following procedure outlines the steps necessary to create
myerson
DuraFlex
Partials with the
myerson
Flexpress
™ Digital
Injection System.
1. Evaluate the model for major undercuts and block out the
undercuts. Due to the flexibility and adjustability of the material,
very little if any blocking out will be needed.
2. Paint the model with myerson Thermoplastic Model Separator
MS-0200
.
7
section 6 ~
processing using the
“Re-run Last Profile”
1. From the main menu use the
UP or DOWN
buttons until the cursor
is to the left of “Rerun Last Profile” then press the enter button.
2. The display will show the profile name and profile settings of the
last injection. If this is not the profile you wish to run, press the
LEFT arrow button to return to the main menu.
3. The
myerson
Flexpress
™ is now ready to process your case.
See steps 5-13 of Section 5 for a complete injection.
12. Press the
EXTEND/RETRACT
button again to retract the piston.
13. The
myerson
Flexpress
™ is now ready to process another case.
Repeat steps 1-9 for your next injection.