5
section 4 ~ editing user profiles
The
myerson FlexPress
allows the user to save up to 7 custom
processing profiles for easy switching between materials. The following
procedure outlines how to create and save profiles in the
myerson
FlexPress
™ Digital Injection System. Note:
myerson, LLC
does not
provide process settings for materials other than
myerson, LLC
supplied materials. Refer to the manufacturer supplied information
for processing settings.
1. From the main menu, use the
UP/DOWN
buttons until
“Edit User Profile”
is displayed. Press the
ENTER
button
to select.
2. Using the
UP/DOWN
buttons until the “Spare” location to be
edited is displayed. Press the
ENTER
button to select.
3. The first parameter to be modified is the “Name” of the spare
profile. Press the
ENTER
button and a flashing cursor should
appear. Using the
LEFT/RIGHT
buttons to move the cursor to
the character location you wish to modify. Once the cursor is
in position, use the
UP/DOWN
buttons to scroll through the
available characters. Press the
ENTER
button when finished.
4. Press the
DOWN
button and the “Melt Temperature” parameter
will be displayed. Press the
ENTER
button and a flashing cursor
will appear. Use the UP/DOWN buttons to change the Melt
temperature to the desired value. Once finished press the
ENTER
button.
5. Repeat step 4 for the
“Melt Time”
and “Hold Time”parameters.
6. Once satisfied with the changes, press the LEFT button. The
screen should display
“Saving Changes”
. The profile you just
created will now appear in the
“Run Stored Profile”
option in
the main menu.